6.04 Guide for Selecting Filler Wire Diameter<br />

Filler Wire Diameter AC Current Range<br />

(Amps)<br />

32<br />

DC Current Range<br />

(Amps)<br />

1/16” (1.6 mm) 30 - 95 20 - 90<br />

3/32” (2.4 mm) 125 - 160 65 - 115<br />

1/8” (3.2 mm) 180 - 240 100 - 165<br />

3/16” (4.8 mm) 220 - 320 200 - 350<br />

Table 9 – Filler Wire Selection Guide<br />

NOTE 1<br />

The filler wire diameter specified in the above table is a guide only, other diameter wires may be<br />

used according to the welding application.<br />

6.05 Shielding Gas Selection<br />

Alloy Shielding Gas<br />

Argoshield is a registered trademark of BOC Gases Limited.<br />

Aluminium & alloys Welding Argon, Argoshield 80T, 81T<br />

Carbon Steel Welding Argon<br />

Stainless Steel Welding Argon, Argoshield 71T, 80T, 81T<br />

Nickel Alloy Welding Argon, Argoshield 71T<br />

Copper Welding Argon, Argoshield 81T<br />

Titanium Welding Argon, Argoshield 80T, 81T<br />

Table 10 – Shielding Gas Selection<br />

6.06 TIG Welding Parameters for Low Carbon & Low Alloy Steel Pipe<br />

Electrode Type &<br />

Diameter<br />

Thoriated 2%<br />

3/32” (2.4 mm)<br />

Thoriated 2%<br />

3/32” (2.4 mm)<br />

Thoriated 2%<br />

3/32” (2.4 mm)<br />

Current Range DC<br />

Amperes<br />

Filler Rod for<br />

Root Pass<br />

120 - 170 Yes<br />

100 - 160 Yes<br />

90 - 130 No<br />

Joint Preparation<br />

Table 11 – TIG Welding Parameters for Low Carbon & Low Alloy Steel Pipe