5.03 MIG Welding<br />

• Connect work lead to negative terminal<br />

• Connect electrode lead to positive terminal<br />

• Switch machine on<br />

• Set weld voltage<br />

• Set Inductance<br />

• Connect Wire feeder<br />

• Set wire feed speed (IPM)<br />

Use the Scroll Buttons to move to the parameter to be set. The LED will show which function is being<br />

adjusted on the weld sequence graph. Use the control knob to adjust each parameter.<br />

Commence welding<br />

5.04 Save-Load Operation<br />

A total number of 5 programs can be saved into the 400 MST memory.<br />

SAVE the Current Weld Parameters into Memory<br />

• Press and HOLD the SAVE button. Beep will sound and Digital Meter display will show a number 1.<br />

• Select a memory location by rotating the control knob, 1 to 5 is displayed on the meter.<br />

• After selecting the desired memory location (i.e. 1 to 5), press the right scroll button and the<br />

machine will give a beep to confirm the weld parameters from the control panel are saved.<br />

LOAD (retrieve) a Program to Control Panel<br />

• Press and HOLD the LOAD button. Beep will sound and Digital Meter display will show a number 1.<br />

• Select a memory location by rotating the control knob, 1 to 5 is displayed on the meter.<br />

• After selecting the desired memory location (i.e. 1 to 5), press the right scroll button and the<br />

machine will give a beep to confirm the weld parameters are loaded onto the control panel.<br />