3. Open or improperly connected ribbon cable to J2<br />

connector on Main PCB 1<br />

a) Inspect connaction and check continuity. Replace<br />

if open.<br />

4) Defective Main PCB 1.<br />

a) Replace Main PCB 1.<br />

F. UNDER PRESSURE FAULT. AC LED on,<br />

FAULT Indicator and 60 PSI LED flashing.<br />

1. Air pressure source to unit is too low.<br />

a) Set input pressure source to 90-100PSI.<br />

2. Regulator set too low.<br />

a) Adjust unit regulator to increase pressure.<br />

3. Defective Logic PCB 3<br />

a) Measure for 5VDC on the Logic PCB 3 between<br />

J3-3 to J3-1. Replace Logic PCB 3 if voltage is<br />

not present or low.<br />

b) Measure for voltage on the Logic PCB 3 between<br />

J3-2 to J3-1. If the voltage is between<br />

3-4.5VDC, replace the Logic PCB 3.<br />

4. Defective Pressure Transducer<br />

a) Replace Pressure Transducer<br />

G. INPUT POWER FAULT. AC LED on, FAULT<br />

Indicator and 65 PSI LED flashing.<br />

1. Primary line voltage out of tolerance range.<br />

a) Connect unit to voltage with unit specifications.<br />

See section "2.04 Power supply specifications".<br />

If using a generator, connect unit<br />

to a wall receptacle to see if problem is corrected.<br />

2 Defective Main PCB 1<br />

a) Measure voltage on Main PCB 1 between test<br />

point GND1 to J2-22.<br />

400 VAC input = approx 2.6 VDC<br />

If voltage is less than 2vdc, replace Main PCB 1.<br />

3. Defective Ribbon cable.<br />

a) Check continuity of the ribbon cable connecting<br />

between the Main PCB 1 and the Logic<br />

PCB 3.<br />

4. Defective Logic PCB 3.<br />

a) Replace Logic PCB 3.<br />

CUTMASTER 25mm<br />

H. PARTS-IN-PLACE (PIP) FAULT. The FAULT<br />

Indicator and 70 PSI LED is flashing. After<br />

20 seconds fan MOT1 turns on.<br />

1. Shield Cup loose<br />

a) Hand tighten the shield cup to close the PIP<br />

switch<br />

2. Torch not properly connected to power supply<br />

a) Insure torch ATC is securely fastened to unit.<br />

3. Problem with torch and leads PIP circuit<br />

a) Check continuity of torch PIP circuit at ATC<br />

pins 1 & 2.<br />

Negative / Plasma Lead<br />

4 Torch Switch<br />

3 Torch Switch<br />

<strong>Manual</strong> 0-5081 5-13 SERVICE<br />

2 PIP<br />

1 PIP<br />

Pilot Lead<br />

4. Defective Logic Pcb<br />

Art # A-08124<br />

a) Measure the voltage on Main Pcb between J2-17<br />

to test point GND1 for 12VDC. If the voltage<br />

is less than 2VDC, Replace Logic Pcb<br />

5. Defective Main Pcb<br />

a) Replace Main Pcb