20.08.2013 Views

CutMaster True Service Manual - Victor Technologies - Europe

CutMaster True Service Manual - Victor Technologies - Europe

CutMaster True Service Manual - Victor Technologies - Europe

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

CUTMASTER 25mm<br />

3.04 Gas Connections<br />

Connecting Gas Supply to Unit<br />

The connection is the same for compressed air or high pressure cylinders. Refer to the following two<br />

subsections if an optional air line filter is to be installed.<br />

1. Connect the air line to the inlet port. The illustration shows typical fittings as an example.<br />

NOTE<br />

For a secure seal, apply thread sealant to the fitting threads, according to manufacturer's instructions. Do not<br />

use Teflon tape as a thread sealer, as small particles of the tape may break off and block the small air passages in<br />

the torch.<br />

Hose Clamp<br />

Gas Supply<br />

Hose<br />

Art # A-07943<br />

Regulator/Filter<br />

Assembly<br />

Air Connection to Inlet Port<br />

Inlet Port<br />

1/4 NPT or ISO-R<br />

to 1/4” (6mm) Fitting<br />

INSTALLATION 3-4 <strong>Manual</strong> 0-5081