3RT, 3RH, 3TB, 3TC, 3TH, 3TK Contactors for Special Applications<br />

■ Overview<br />

AC and DC operation (size S3)<br />

UC operation (AC/DC) (sizes S6 to S12)<br />

IEC 60947, <strong>EN</strong> 60947 (VDE 0660)<br />

The contactors are suitable for use in any climate. They are<br />

finger-safe according to <strong>EN</strong> 50274.<br />

■ Technical specifications<br />

Contactors Type 3RT14 46<br />

General data<br />

Size S3<br />

Permissible mounting position<br />

The contactors are designed for<br />

operation on a vertical mounting<br />

surface.<br />

AC and DC operation<br />

360°<br />

Upright mounting position: AC operation<br />

3RT14 Contactors for Switching Resistive Loads (AC-1)<br />

DC operation<br />

Special version required.<br />

--<br />

Mechanical endurance Operating<br />

cycles<br />

10 million<br />

Electrical endurance in operating cycles<br />

Utilization category AC-1 at I e<br />

3-pole, 140 ... 690 A<br />

3RT14 contactors are used for switching resistive loads (AC-1)<br />

or as contactors, for example, for variable-speed operating<br />

mechanisms that normally only have to carry the current.<br />

The accessories for the 3RT10 contactors can also be used<br />

here.<br />

For more detailed descriptions about the sizes S6 to S12, see<br />

"3RT10 Contactors, 3-pole, 3 ... 250 kW".<br />

Operating<br />

cycles<br />

Rated insulation voltage U i (degree of pollution 3) V 1000<br />

Rated impulse withstand voltage U imp kV 6<br />

Protective separation between the coil and the main contacts<br />

acc. to <strong>EN</strong> 60947-1, Appendix N<br />

© Siemens AG <strong>2009</strong><br />

V 690<br />

For DC operation and 22.5 °C inclination towards the front,<br />

operating range 0.85 ... 1.1 x U s<br />

5 * " % % =<br />

0.5 million<br />

30° 30°<br />

Mirror contacts<br />

- Removable auxiliary switch block Yes, acc. to <strong>EN</strong> 60947-4-1, Appendix F<br />

A mirror contact is an auxiliary NC - Permanently fitted auxiliary<br />

Acc. to Swiss regulations (SUVA) on request<br />

contact that cannot be closed simultaneously<br />

with a NO main contact.<br />

switch block<br />

Permissible ambient temperature During operation °C -25 ... +60<br />

During storage °C -55 ... +80<br />

Degree of protection acc. to <strong>EN</strong> 60947-1, Appendix C IP20 (terminal compartment IP00),<br />

AC coil assembly IP40,<br />

DC coil assembly IP30<br />

Touch protection acc. to <strong>EN</strong> 50274<br />

Shock resistance<br />

Finger-safe<br />

Rectangular pulse AC and DC operation g/ms 6.8/5 and 4/10<br />

Sine pulse AC and DC operation g/ms 10.6/5 and 6.2/10<br />

Conductor cross-sections<br />

1)<br />

Short-circuit protection for contactors without overload relays<br />

Main circuit<br />

Fuse links, gL/gG operational class,<br />

LV HRC, 3NA<br />

Type of coordination "1": A 250<br />

Fuse links, gR operational class,<br />

SITOR 3NE<br />

Auxiliary circuit<br />

Type of coordination "2" A 250<br />

Fuse links gL/gG (weld-free protection at Ik ≥1 kA)<br />

DIAZED 5SB, NEOZED 5SE<br />

A 10<br />

Or miniature circuit breakers with C characteristic (Ik < 400 A)<br />

1) For conductor cross-sections see page 3/96.<br />

A 10<br />

NSB0_00478b<br />

Siemens LV 1 T · <strong>2009</strong><br />

3/93<br />