3<br />

3RT, 3TB, 3TF Contactors for Switching Motors<br />

3RT10 contactors, 3-pole, 3 ... 250 kW<br />

Contactors Type 3RT10 5.<br />

Size S6<br />

Conductor cross-sections of main conductors with box terminal<br />

(1 or 2 conductors can be<br />

connected)<br />

Front or rear clamping point<br />

connected<br />

<br />

Both clamping points<br />

connected<br />

<br />

(1 or 2 conductors can be<br />

connected)<br />

Front or rear clamping point<br />

connected<br />

<br />

Both clamping points<br />

connected<br />

<br />

For tools for opening Cage Clamp terminals see <strong>Catalog</strong> LV 1,<br />

<strong>Chapter</strong> 3, Accessories and Spare Parts.<br />

Maximum external diameter of the conductor insulation: 3.6 mm.<br />

For conductor cross-sections ≤ 1 mm² an "insulation stop" must<br />

be used, see <strong>Catalog</strong> LV 1, <strong>Chapter</strong> 3, "Accessories and Spare<br />

Parts".<br />

1) When connecting cable lugs to DIN 46235, use 3RT19 56-4EA1 terminal<br />

cover for conductor cross-sections from 95 mm² to ensure phase spacing.<br />

2) If two different conductor cross-sections are connected to one clamping<br />

point, both cross-sections must lie in the range specified. If identical crosssections<br />

are used, this restriction does not apply.<br />

3/42<br />

<br />

<br />

Siemens LV 1 T · <strong>2009</strong><br />

Main conductors:<br />

With 3RT19 55-4G box terminal (55 kW)<br />

Screw terminals<br />

Finely stranded with end sleeve mm² 16 ... 70<br />

Finely stranded without end sleeve mm² 16 ... 70<br />

Stranded mm² 16 ... 70<br />

Ribbon cable conductors<br />

mm Min. 3 x 9 x 0.8, max. 6 x 15.5 x 0.8<br />

(number x width x thickness)<br />

AWG cables,<br />

solid or stranded<br />

AWG 6 ... 2/0<br />

Finely stranded with end sleeve mm² Max. 1 x 50, 1 x 70<br />

Finely stranded without end sleeve mm² Max. 1 x 50, 1 x 70<br />

Stranded mm² max. 2 x 70<br />

Ribbon cable conductors<br />

mm Max. 2 x (6 x 15.5 x 0.8)<br />

(number x width x thickness)<br />

AWG cables,<br />

solid or stranded<br />

AWG Max. 2 x 1/0<br />

Terminal screw M10 (hexagon socket, A/F 4)<br />

- Tightening torque<br />

Main conductors:<br />

With 3RT19 56-4G box terminal<br />

Nm 10 ... 12 (90 ... 110 lb.in)<br />

Finely stranded with end sleeve mm² 16 ... 120<br />

Finely stranded without end sleeve mm² 16 ... 120<br />

Stranded mm² 16 ... 120<br />

Ribbon cable conductors<br />

mm Min. 3 x 9 x 0.8, max. 10 x 15.5 x 0.8<br />

(number x width x thickness)<br />

AWG cables,<br />

solid or stranded<br />

AWG 6 ... 250 kcmil<br />

Finely stranded with end sleeve mm² Max. 1 x 95, 1 x 120<br />

Finely stranded without end sleeve mm² Max. 1 x 95, 1 x 120<br />

Stranded mm² Max. 2 x 120<br />

Ribbon cable conductors<br />

mm Max. 2 x (10 x 15.5 x 0.8)<br />

(number x width x thickness)<br />

© Siemens AG <strong>2009</strong><br />

AWG cables,<br />

solid or stranded<br />

AWG Max. 2 x 3/0<br />

Terminal screw M10 (hexagon socket, A/F 4)<br />

- Tightening torque<br />

Main conductors:<br />

Without box terminal/busbar connection<br />

Nm 10 ... 12 (90 ... 110 lb.in)<br />

Finely stranded with cable lug1) mm2 Stranded with cable lug<br />

16 ... 95<br />

1)<br />

mm 2<br />

25 ... 120<br />

AWG cables,<br />

solid or stranded<br />

AWG 4 ... 250 kcmil<br />

Connecting bar (max. width) mm 17<br />

Terminal screw M8 x 25 (A/F 13)<br />

- Tightening torque<br />

Auxiliary conductors:<br />

Nm 10 ... 14 (89 ... 124 lb.in)<br />

Solid mm 2<br />

2 x (0.5 ... 1.5) 2) ; 2 x (0.75 ... 2.5) 2) acc. to IEC 60947;<br />

max. 2 x (0.75 ... 4)<br />

Finely stranded with end sleeve mm 2<br />

2 x (0.5 ... 1.5) 2) ; 2 x (0.75 ... 2.5) 2)<br />

AWG cables, solid or stranded AWG 2 x (18 ... 14)<br />

Terminal screw M3 (PZ 2)<br />

- Tightening torque Nm 0.8 ... 1.2 (7 ... 10.3 lb.in)<br />

Auxiliary conductors: Cage Clamp terminals<br />

Solid mm2 Finely stranded with end sleeve mm<br />

2 x (0.25 ... 2.5)<br />

2<br />

Finely stranded without end sleeve mm<br />

2 x (0.25 ... 1.5)<br />

2<br />

2 x (0.25 ... 2.5)<br />

AWG cables,<br />

solid or stranded<br />

AWG 2 x (24 ... 14)