3RT, 3TB, 3TF Contactors for Switching Motors<br />
3RT10 contactors, 3-pole, 3 ... 250 kW<br />
Contactors Type 3RT10 34 3RT10 35 3RT10 36<br />
Main circuit<br />
AC capacity<br />
Size S2 S2 S2<br />
Utilization category AC-5b<br />
Switching incandescent lamps<br />
Per main current path at 230/220 V<br />
kW 6.0 7.6 9.5<br />
Utilization category AC-6a<br />
switching AC transformers<br />
Rated operational current Ie - For inrush current n = 20 Up to 400 V A 31 36.5 43.2<br />
- For inrush current n = 30<br />
Rating P<br />
Up to 400 V A 20.7 24.3 28.8<br />
- For inrush current n = 20 At 230 V kVA 12.3 14.5 17.2<br />
400 V kVA 21.5 25.3 29.9<br />
500 V kVA 26.8 31.6 37.4<br />
690 V kVA 23.9 28.7 28.7<br />
- For inrush current n = 30 230 V kVA 8.2 9.7 11.5<br />
400 V kVA 14.3 16.8 20<br />
500 V kVA 17.9 21 24.9<br />
690 V kVA 23.9 28.7 28.7<br />
For deviating inrush current factors x, the power must be recalculated as follows.<br />
Px = Pn30 ⋅ 30/x<br />
Utilization category AC-6b<br />
Switching low-inductance (low-loss, metallized dielectric) AC capacitors<br />
Ambient temperature 40 °C<br />
Rated operational currents Ie Up to 400 V A 29 36 36<br />
Rated power for single capacitors or<br />
banks of capacitors (minimum inductance<br />
of 20 µH between capacitors<br />
connected in parallel) at 50 Hz, 60 Hz<br />
and<br />
Load rating with DC<br />
Utilization category DC-1<br />
Switching resistive loads (L/R < 1 ms)<br />
Rated operational current I e (at 60 °C)<br />
At 230 V kvar 12 15 15<br />
400 V kvar 20 25 25<br />
525 V kvar 25 33 33<br />
690 V kvar 20 25 25<br />
- 1 conducting path Up to 24 V A 45 55 55<br />
60 V A 20 23 23<br />
110 V A 4.5 4.5 4.5<br />
220 V A 2 2 2<br />
440 V A 0.4 0.4 0.4<br />
600 V A 0.25 0.25 0.25<br />
- 2 conducting paths in series Up to 24 V A 45 55 55<br />
60 V A 45 45 45<br />
110 V A 45 45 45<br />
220 V A 5 5 5<br />
440 V A 1 1 1<br />
600 V A 0.8 0.8 0.8<br />
- 3 conducting paths in series Up to 24 V A 45 55 55<br />
60 V A 45 55 55<br />
110 V A 45 55 55<br />
220 V A 45 45 45<br />
440 V A 2.9 2.9 2.9<br />
Utilization category DC-3 and DC-5<br />
Shunt-wound and series-wound motors (L/R ≤ 15 ms)<br />
600 V A 1.4 1.4 1.4<br />
Rated operational current I e (at 60 °C)<br />
© Siemens AG <strong>2009</strong><br />
- 1 conducting path Up to 24 V A 35 35 35<br />
60 V A 6 6 6<br />
110 V A 2.5 2.5 2.5<br />
220 V A 2 2 2<br />
440 V A 0.1 0.1 0.1<br />
600 V A 0.06 0.06 0.06<br />
- 2 conducting paths in series Up to 24 V A 45 55 55<br />
60 V A 45 45 45<br />
110 V A 25 25 25<br />
220 V A 5 5 5<br />
440 V A 0.27 0.27 0.27<br />
600 V A 0.16 0.16 0.16<br />
- 3 conducting paths in series Up to 24 V A 45 55 55<br />
60 V A 45 55 55<br />
110 V A 45 55 55<br />
220 V A 25 25 25<br />
440 V A 0.6 0.6 0.6<br />
600 V A 0.6 0.6 0.6<br />