3RT, 3TB, 3TF Contactors for Switching Motors<br />
3RT10 contactors, 3-pole, 3 ... 250 kW<br />
Contactors Type 3RT10 23 3RT10 24 3RT10 25 3RT10 26<br />
Main circuit<br />
AC capacity<br />
Utilization category AC-4 (for Ia = 6 x Ie) Size S0 S0 S0 S0<br />
Rated operational current Ie Up to 400 V A 8.5 12.5 15.5 15.5<br />
Rated power for squirrel-cage motors<br />
with 50 Hz and 60 Hz<br />
The following applies to a contact endurance<br />
of about 200000 operating cycles:<br />
At 400 V kW 4 5.5 7.5 7.5<br />
- Rated operational currents Ie Up to 400 V<br />
690 V<br />
A<br />
A<br />
4.1<br />
3.3<br />
5.5<br />
5.5<br />
7.7<br />
7.7<br />
9<br />
9<br />
- Rated power for squirrel-cage motors<br />
with 50 Hz and 60 Hz<br />
1) For Ie /AC-1 = 35 A (60 °C) and the corresponding minimum conductor<br />
cross-section 10 mm 2 .<br />
2) Depending on the electronic ballast used, higher lamp numbers are also<br />
possible.<br />
3/26<br />
Siemens LV 1 T · <strong>2009</strong><br />
At 110 V kW 0.5 0.73 1 1.2<br />
230 V kW 1.1 1.5 2 2.5<br />
400 V kW 2 2.6 3.5 4.4<br />
500 V kW 2 3.3 4.6 5.6<br />
690 V kW 2.5 4.6 6 7.7<br />
Utilization category AC-5a<br />
Switching gas discharge lamps, inductive ballast<br />
Per main current path at 230 V1) Rated power per lamp/rated operational current per lamp<br />
- Uncorrected L 18 W/0.37 A Units 108<br />
L 36 W/0.43 A Units 93<br />
L 58 W/0.67 A Units 59<br />
L 80 W/0.79 A Units 50<br />
- DUO switching (two-lamp) L 18 W/0.22 A Units 181 (r 2x181 lamps)<br />
L 36 W/0.42 A Units 95 (r 2x95 lamps)<br />
L 58 W/0.63 A Units 63 (r 2x63 lamps)<br />
Switching gas discharge lamps with correction<br />
Per main current path at 230 V<br />
Rated power per lamp/capacitance/rated<br />
operational current per lamp<br />
L80W/0.87A Units45 (r 2x45 lamps)<br />
- Shunt compensation with inductive<br />
ballast<br />
L 18 W/4.5 μF/0.11 A Units 37 41 61<br />
L 36 W/4.5 μF/0.21 A Units 30 30 51<br />
L 58 W/7.0 μF/0.32 A Units 20 20 33<br />
L 80 W/7.0 μF/0.49 A Units 13 13 22<br />
- With solid-state ballast 2) single lamp L 18 W/6.8 μF/0.10 A Units 105 119 175<br />
L 36 W/6.8 μF/0.18 A Units 58 66 97<br />
L 58 W/10 μF/0.29 A Units 36 41 60<br />
L 80 W/10 μF/0.43 A Units 24 27 40<br />
- With solid-state ballast 2) two-lamp L 18 W/10 μF/0.18 A Units 58 (r 2x58 lamps) 66 (r 2x66 l.) 97 (r 2x97 l.)<br />
L 36 W/10 μF/0.35 A Units 30 (r 2x30 lamps) 34 (r 2x34 l.) 50 (r 2x50 l.)<br />
L 58 W/22 μF/0.52 A Units 20 (r 2x20 lamps) 22 (r 2x22 l.) 33 (r 2x33 l.)<br />
L 80 W/22 μF/0.86 A Units 12 (r 2x12 lamps) 13 (r 2x13 l.) 20 (r 2x20 l.)<br />
Utilization category AC-5b, switching incandescent lamps<br />
per main current path at 230/220 V<br />
kW 2.8 3.2 4.7<br />
Utilization category AC-6a<br />
switching AC transformers<br />
Rated operational current Ie - For inrush current n = 20 Up to 400 V A 11.4 20.2<br />
- For inrush current n = 30<br />
Rating P<br />
Up to 400 V A 7.6 13.5<br />
- For inrush current n = 20 At 230 V kVA 4.5 8<br />
400 V kVA 7.9 13.9<br />
500 V kVA 9.9 15.5<br />
690 V kVA 13.6 15.5<br />
- For inrush current n = 30 At 230 V kVA 3 5.4<br />
400 V kVA 5.2 9.3<br />
500 V kVA 6.6 11.7<br />
690 V kVA 9.1 15.5<br />
For deviating inrush current factors x, the power must be recalculated as follows:<br />
Px = Pn30 ⋅ 30/x<br />
Utilization category AC-6b,<br />
switching low-inductance (low-loss, metallized dielectric) AC capacitors<br />
Rated operational currents Ie Up to 400 V A 5.8 10.8<br />
Rated power for single capacitors or<br />
banks of capacitors (minimum inductance<br />
of 6 µH between capacitors connected<br />
in parallel) at 50 Hz, 60 Hz and<br />
© Siemens AG <strong>2009</strong><br />
At 230 V kvar 2.5 4<br />
400 V kvar 4 7.5<br />
500 V kvar 4 7.5<br />
690 V kvar 4 7.5