Catalog LV1 T 2009 Chapter 3 EN
Catalog LV1 T 2009 Chapter 3 EN
Catalog LV1 T 2009 Chapter 3 EN
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Contactors Type 3RT19 26-2P.<br />
Pneumatic delay block 1)<br />
General data<br />
Mechanical endurance Operating<br />
cycles<br />
Electrical endurance at I e<br />
Rated insulation voltage U i<br />
(degree of pollution 3)<br />
Permissible ambient temperature<br />
1) For size S0.<br />
In addition to the pneumatic delay block, no other auxiliary contacts are<br />
permitted.<br />
Accessories and Spare Parts<br />
For 3RT, 3RH Contactors and Contactor Relays<br />
Accessories for 3RT, 3RH contactors<br />
and contactor relays<br />
Operating<br />
cycles<br />
V 690<br />
5 million<br />
1 million<br />
During operation °C -25 ... +60<br />
During storage<br />
Rated operational currents Ie Acc. to utilization categories <strong>EN</strong> 60947<br />
°C -50 ... +80<br />
AC-12 A 10<br />
AC-15/AC-14 at Ue Up to 230/220 V A<br />
400/380 V A<br />
6<br />
4<br />
500 V A 2.5<br />
690/660 V A 1.5<br />
DC-13 at Ue 24 V A<br />
48 V A<br />
4<br />
2<br />
110 V A 0.7<br />
220 V A 0.3<br />
Conductor cross-sections<br />
440 V A 0.15<br />
Solid, stranded: mm 2<br />
2 x 0.5 ... 2.5 2) or 2 x 2.5 ... 4 2)<br />
Finely stranded with end sleeve mm² 2 x 0.5 ... 2.5<br />
AWG cables AWG 2 x 22 ... 12<br />
Tightening torque of the terminal screws<br />
Time delay<br />
Nm 0.8 ... 1.1<br />
Accuracy ±10 %<br />
s and u rated data<br />
Rated voltage V AC 600<br />
Switching capacity A 600, Q 600<br />
Versions<br />
Connection modules for contactors with screw terminals<br />
2) If two different conductor cross-sections are connected to one clamping<br />
point, both cross-sections must lie in the range specified. If identical crosssections<br />
are used, this restriction does not apply.<br />
3RT1900-4RE01<br />
plugs S00, S0<br />
General data<br />
Mechanical endurance Operating<br />
cycles<br />
10 million<br />
Electrical endurance at Ie Operating<br />
cycles<br />
1 million<br />
Rated operational voltage Ue V 440<br />
Rated insulation voltage U i<br />
(degree of pollution 3)<br />
Rated impulse withstand voltage U imp<br />
(degree of pollution 3)<br />
Protective separation acc. to <strong>EN</strong> 60947-1<br />
(degree of pollution 3)<br />
Rated operational current I e<br />
AC-3 at 400 V<br />
V 690<br />
kV 6<br />
V 400<br />
Rated frequency f Hz 50/60<br />
For AC operation<br />
Permissible ambient temperature<br />
During operation °C -25 ... +60<br />
During storage °C<br />
-50 ... +80<br />
Degree of protection acc. to <strong>EN</strong> 60529 IP20<br />
Conductor cross-sections<br />
Screw terminals<br />
Solid mm 2<br />
© Siemens AG <strong>2009</strong><br />
3RT1916-4RD01<br />
adapters S00<br />
A 25 20 25<br />
1x (0.5 ... 6)<br />
Finely stranded without/with end sleeve mm² 1x (0.5 ... 6)<br />
Stranded mm² 1x (0.5 ... 6)<br />
AWG cables, solid or stranded AWG 1x (20 ... 10)<br />
Tightening torque Nm 0.6 ... 0.8<br />
Corresponding opening tool Short-slot screwdriver PZ2<br />
3RT1926-4RD01<br />
adapters S0<br />
Siemens LV 1 T · <strong>2009</strong><br />
3/173<br />
3