Maintenance<br />

Figure 6-5 Mounting the tacho-generator<br />

Proceed as follows for assembly:<br />

•= If the coupling on the tacho-generator side was detached, when mounting it<br />

secure the transverse stud bolt or grub screw with removable LOCTITE and fix<br />

it with the appropriate tightening torque:<br />

Table 6-5 Tightening torques for coupling attachment<br />

Thread size Tightening torque [Nm]<br />

M4 1,3<br />

M5 2,6<br />

M6 4,5<br />

•= Take care that the flexible intermediate link (coupling star) is in working order<br />

and in the correct position.<br />

•= Mount the complete tacho-generator.<br />

[ID 590]<br />

6.3.8 Tightening torques of screw connections<br />

Tightening torques<br />

If no other specific details are indicated, the following tightening torques apply to<br />

normal connections of fixing screws/bolts and nuts:<br />

Table 6-6 Tightening torques [Nm ± 10%] for various thread sizes<br />

M4 M5 M6 M8 M10 M12 M16 M20 M24<br />

Case A 1,2 2,5 4,0 8,0 13 20 40 - -<br />

SIEMENS AG T61160347010001 (DMHO V9)<br />

6-18 Operating instructions 1GG6286-0NA4.-1VV1-Z