Maintenance<br />
Figure 6-5 Mounting the tacho-generator<br />
Proceed as follows for assembly:<br />
•= If the coupling on the tacho-generator side was detached, when mounting it<br />
secure the transverse stud bolt or grub screw with removable LOCTITE and fix<br />
it with the appropriate tightening torque:<br />
Table 6-5 Tightening torques for coupling attachment<br />
Thread size Tightening torque [Nm]<br />
M4 1,3<br />
M5 2,6<br />
M6 4,5<br />
•= Take care that the flexible intermediate link (coupling star) is in working order<br />
and in the correct position.<br />
•= Mount the complete tacho-generator.<br />
[ID 590]<br />
6.3.8 Tightening torques of screw connections<br />
Tightening torques<br />
If no other specific details are indicated, the following tightening torques apply to<br />
normal connections of fixing screws/bolts and nuts:<br />
Table 6-6 Tightening torques [Nm ± 10%] for various thread sizes<br />
M4 M5 M6 M8 M10 M12 M16 M20 M24<br />
Case A 1,2 2,5 4,0 8,0 13 20 40 - -<br />