Table 6-4 Recommended torques for tightening the coupling part<br />

Thread size Torque [Nm]<br />

M16 20<br />

M20 30<br />

M24 40<br />

[ID 584]<br />

6.3.5 Assembling the <strong>motor</strong><br />

General<br />

Sealing measures<br />

Maintenance<br />

If possible the <strong>motor</strong> should be assembled on an aligning plate. This ensures that<br />

the position of the brush rocker in relation to the stator housing is correctly set and<br />

the footings are on one level.<br />

Note<br />

When mounting the bearing end shield at the D-end, take care that the windings<br />

protruding from the stator housing are not damaged.<br />

Bare joints between parts (e.g. between housings, bearing end shields and bearing<br />

cartridges) must be cleaned and at least regreased.<br />

If joint sealants have been used where there are higher requirements in terms of<br />

the degree of protection, these joints between parts must likewise be sealed again<br />

during assembly using suitable silicone-free, non-hardening sealing compound. It<br />

is recommended that this sealing compound should then also be used when<br />

inserting the corresponding fixing screws.<br />

If sealing elements are installed, these must be checked and if they are no longer<br />

sufficiently effective they must be replaced.<br />

Screw/bolt locking elements<br />

Screws/bolts or nuts which are mounted together with locking, spring-loaded<br />

and/or force-distributing elements (e.g. safety plates, spring washers, etc.) must be<br />

equipped with identical operational elements again when the <strong>motor</strong> is assembled.<br />

Form-fit locking elements must always be replaced.<br />

When reassembling the <strong>motor</strong>, always install fixing screws with a "clamping length"<br />

< 25 mm with suitable locking elements (spring washers, strain washers and the<br />

like) or with a removable locking agent (e.g. LOCTITE). The clamping length is<br />

taken as the distance between the head of the bolt and the point at which the bolt<br />

is screwed in.<br />

SIEMENS AG T61160347010001 (DMHO V9)<br />

Operating instructions 1GG6286-0NA4.-1VV1-Z 6-15