Maintenance<br />
Warning<br />
Before starting work on the <strong>motor</strong> ensure that the <strong>motor</strong>/plant has been<br />
deenergized in compliance with the appropriate specifications and regulations.<br />
In addition to the main circuits, also ensure that supplementary and auxiliary<br />
circuits are also deenergized, especially the standstill heating.<br />
Dismantling the <strong>motor</strong><br />
Circuit connections<br />
Note<br />
If the <strong>motor</strong> has to be transported, please observe the information and instructions<br />
in section on "Transport and storage". All repair work must always be performed by<br />
suitably qualified expert personnel. If necessary, consult the SIEMENS service<br />
center.<br />
If the <strong>motor</strong> has to be disassembled, it makes sense to disconnect the connecting<br />
cables at the terminals and to detach the entry plate from the terminal box frame.<br />
In this way the positions of the cables in relation to each other and the effective<br />
sealing of the cables in the cable entry points is largely retained. Check the<br />
labeling of the connecting cables, and if defective renew it.<br />
The terminal diagram only shows the conditions required for the supply connection<br />
without taking account of any compensating and auxiliary windings that may be<br />
present. Label internal connections first if they are to be disconnected during<br />
maintenance work.<br />
[ID 582]<br />
6.3.2 Disassembling the <strong>motor</strong><br />
Safety information<br />
Caution<br />
When working on the locating bearing when the <strong>motor</strong> is in its vertical position,<br />
support the rotor.<br />
With vertical attachment of rotors:<br />
The center holes in the shaft ends (DIN 332) have inset threads, i.e. eye-bolts to<br />
DIN 580 are not suitable, as only a few thread turns would be engaged. Depending<br />
on the rotor weight and load direction, the use of other suitable elements with a<br />
screw reach of > 0 0.8 x thread diameter might be necessary.<br />
SIEMENS AG T61160347010001 (DMHO V9)<br />
6-12 Operating instructions 1GG6286-0NA4.-1VV1-Z