Maintenance<br />

Warning<br />

Before starting work on the <strong>motor</strong> ensure that the <strong>motor</strong>/plant has been<br />

deenergized in compliance with the appropriate specifications and regulations.<br />

In addition to the main circuits, also ensure that supplementary and auxiliary<br />

circuits are also deenergized, especially the standstill heating.<br />

Dismantling the <strong>motor</strong><br />

Circuit connections<br />

Note<br />

If the <strong>motor</strong> has to be transported, please observe the information and instructions<br />

in section on "Transport and storage". All repair work must always be performed by<br />

suitably qualified expert personnel. If necessary, consult the SIEMENS service<br />

center.<br />

If the <strong>motor</strong> has to be disassembled, it makes sense to disconnect the connecting<br />

cables at the terminals and to detach the entry plate from the terminal box frame.<br />

In this way the positions of the cables in relation to each other and the effective<br />

sealing of the cables in the cable entry points is largely retained. Check the<br />

labeling of the connecting cables, and if defective renew it.<br />

The terminal diagram only shows the conditions required for the supply connection<br />

without taking account of any compensating and auxiliary windings that may be<br />

present. Label internal connections first if they are to be disconnected during<br />

maintenance work.<br />

[ID 582]<br />

6.3.2 Disassembling the <strong>motor</strong><br />

Safety information<br />

Caution<br />

When working on the locating bearing when the <strong>motor</strong> is in its vertical position,<br />

support the rotor.<br />

With vertical attachment of rotors:<br />

The center holes in the shaft ends (DIN 332) have inset threads, i.e. eye-bolts to<br />

DIN 580 are not suitable, as only a few thread turns would be engaged. Depending<br />

on the rotor weight and load direction, the use of other suitable elements with a<br />

screw reach of > 0 0.8 x thread diameter might be necessary.<br />