Maintenance<br />

see also<br />

check, while the <strong>motor</strong> is at standstill, that:<br />

•= the <strong>motor</strong> foundation has no indentations or cracks.<br />

•= the carbon brushes and the commutator are in perfect condition and the<br />

commutator contact surfaces have a uniform skin.<br />

•= the brush holders are correctly aligned and secured.<br />

•= the carbon brushes in the brush boxes and the brush pressure fingers in the<br />

links move easily and the spring action of all carbon brushes is even.<br />

•= the remaining brush height is still sufficient to ensure uninterrupted operation up<br />

until the next inspection. Make sure the height does not drop below the<br />

minimum brush height.<br />

Any defects detected in the course of the inspection must be corrected<br />

immediately.<br />

Note<br />

The range of servicing measures to be performed may increase depending on the<br />

plant specification and operating conditions.<br />

[ID 579]<br />

6.2.2 Main service<br />

Service intervals<br />

Inspection checklist [→ Page 9-3]<br />

A main service must be performed on the <strong>motor</strong> after every approximately 16,000<br />

operating hours or at the latest after 2 years of operation.<br />

Action to be performed<br />

Danger<br />

If no inspection windows are fitted and therefore the respective covers need to be<br />

removed in order to observe the commutation behavior, this must always be done<br />

by specially qualified expert personnel in order to reliably ensure that no live or<br />

moving parts are touched.<br />

Protective goggles must be worn.<br />

With the <strong>motor</strong> running, check that:<br />

•= the specified technical data is complied with (such as power consumption,<br />

temperature of the windings, bearings, coolant, etc.).<br />

SIEMENS AG T61160347010001 (DMHO V9)<br />

6-10 Operating instructions 1GG6286-0NA4.-1VV1-Z