19.08.2013 Views

DC motor - Siemens, s.r.o.

DC motor - Siemens, s.r.o.

DC motor - Siemens, s.r.o.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

6.1.10 Maintenance of the terminal boxes<br />

Leakproofness<br />

Maintenance<br />

Check terminal boxes regularly for leakproofness, deposits of carbon dust,<br />

damaged insulation and firm connections.<br />

If dust or moisture has penetrated into the terminal box, clean and dry the box and<br />

in particular the insulators. Also check seals and sealing surfaces and eliminate the<br />

cause of the leakiness.<br />

Loading with high current<br />

6.2 Servicing<br />

If the terminal box or <strong>motor</strong> has been exposed to loading with extreme high current,<br />

the electrical components must be checked.<br />

[ID 578]<br />

6.2.1 First service<br />

Service intervals<br />

The first service is normally carried out approximately 500 operating hours after the<br />

<strong>motor</strong> has been installed or repaired. The follow-up services must be carried out<br />

after 2000 operating hours in each case.<br />

Action to be performed<br />

Danger<br />

If no inspection windows are fitted and therefore the respective covers need to be<br />

removed in order to observe the commutation behavior, this must always be done<br />

by specially qualified expert personnel in order to reliably ensure that no live or<br />

moving parts are touched.<br />

Protective goggles must be worn.<br />

For the first service and for follow-up services, with the <strong>motor</strong> running check that:<br />

•= the specified technical data is complied with, such as power consumption,<br />

temperature of the windings, bearings, coolant, etc..<br />

•= no leaks occur (oil, grease, water).<br />

•= the smooth running characteristics and bearing noise of the <strong>motor</strong> have not<br />

deteriorated.<br />

•= no unpermissible brush sparking occurs during operation.<br />

SIEMENS AG T61160347010001 (DMHO V9)<br />

Operating instructions 1GG6286-0NA4.-1VV1-Z 6-9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!