Maintenance<br />

Warning<br />

Especially when carrying out cleaning work with compressed air, ensure that<br />

suitable extraction measures are used and you use personal protective gear<br />

(goggles, face mask/filter or similar).<br />

Removing the carbon dust<br />

see also<br />

Deposits of carbon dust on insulating parts must be removed in their entirety, for<br />

example with a brush and suitable extraction device. Motors with a closed internal<br />

circuit without a fine dust filter must be dismantled after about three brush sets<br />

have been worn down and the carbon dust must be thoroughly cleaned from<br />

everything.<br />

Note<br />

When cleaning the brush rockers, take care if a brush-height monitoring device is<br />

fitted that its actuating mechanism is not damaged.<br />

Notice<br />

On fan units with sound absorbers, the surface of the sound absorber elements is<br />

pressure-sensitive. Do not, therefore, clean this directly with compressed air.<br />

Proceed only as follows: carefully brush off large collections of dust that can be<br />

sucked up as a whole by the air flow. If filter mats are fouled, either replace them<br />

or remove them, wash them out in the normal way, dry them and reinstall them<br />

unwetted.<br />

After completing cleaning, check the insulation resistance.<br />

[ID 571]<br />

Checking the insulation resistance [→ Page 4-3]<br />

6.1.5 Maintenance of the carbon brushes<br />

General<br />

When carbon brushes are replaced it must be ensured that the design of the new<br />

carbon brushes matches that of the worn brushes.<br />

The brush type and manufacturer's mark are shown on the upper part of the brush<br />

on carbon brushes.<br />

Warning<br />

When working with brush holders there is a risk of personal injury or material<br />

damage when open pressure levers spring back.<br />

[ID 573]<br />

SIEMENS AG T61160347010001 (DMHO V9)<br />