Relubrication<br />

Maintenance<br />

These greases have Lithium soap as thickening agent and mineral oil as the basic<br />

oil. They exceed the standard requirements of DIN 51825.<br />

When using other K3K or K3N greases, which in some cases only fulfill the<br />

minimum requirements in accordance with DIN 51825, regreasing intervals must<br />

be halved. K3N greases have higher temperature reserves than K3K greases.<br />

Caution<br />

Greases with different thickening agents and basic oils must not be mixed.<br />

Special types of grease are used on <strong>motor</strong>s intended for operational temperatures<br />

below –20 °C. These are specified on the lubrication instruction plate. No other<br />

grease types are permitted.<br />

For relubrication, clean the grease nipples, then press in the quantity and type of<br />

grease according to the lubrication instruction plate. The shaft must rotate so that<br />

the new grease can be distributed throughout the bearing. The bearing<br />

temperature rises sharply at first, then drops to the normal value again when the<br />

excess grease is displaced out of the bearing. The consumed grease is collected<br />

outside the bearing. To remove the used grease, detach the outer bearing cover.<br />

The used grease compartment is suitable for holding the grease from approx. 10<br />

relubrication processes with the prescribed quantity of grease according to the<br />

lubrication instruction plate.<br />

Warning<br />

Whenever you work on the locating bearing when the three-phase <strong>motor</strong> is in its<br />

vertical position, support/unload the rotor.<br />

[ID 570]<br />

6.1.4 Cleaning<br />

Cleaning the cooling-air passages<br />

The cooling-air passages through which ambient air flows must be cleaned at<br />

regular intervals. The cleaning intervals depend on the degree of contamination. In<br />

addition, the internal cooling-air passages (where accessible) and the insulating<br />

parts of the commutator and the brush holder must also be cleaned each time a<br />

worn brush set is replaced.<br />

SIEMENS AG T61160347010001 (DMHO V9)<br />

Operating instructions 1GG6286-0NA4.-1VV1-Z 6-3