Operation<br />

Overview - faults with the commutator<br />

material of brushes<br />

X Temporary overload Correct current limit<br />

X Overload at standstill Correct current limit / shorten<br />

standstill time<br />

Cooling fault<br />

X Cooling air too moist Change routing of cooling air<br />

X X Cooling air chemically aggressive Change routing of cooling air<br />

X Cooling air too dusty Change routing of cooling<br />

air, use air filter<br />

X Cooling-air rate too high (commutator<br />

temperature too low)<br />

Brush fault<br />

Restrict air intake (if nec.<br />

change brush material)<br />

X Incorrect or unsuitable brush material Change brush material<br />

X Brushes not in neutral zone Correct adjustment<br />

Component fault<br />

X Break in armature winding Repair winding<br />

X Defective soldered joint Resolder joint<br />

X X Distorted commutator Rework commutator<br />

X Conductive inclusions in segment slots Mill out segment insulation<br />