Operation<br />

↓ Bearing squeaks<br />

↓ Bearing knocks<br />

Overview - bearing faults<br />

Possible cause of fault Remedial measures<br />

X Too much grease in bearing Remove excess grease<br />

X Felt rings pressing on shaft Fit felt rings better or replace with new<br />

ones<br />

X Coupling pressing Align <strong>motor</strong> more precisely<br />

X Belt tension too high Reduce belt tension<br />

X Bearing soiled Clean or replace bearing; check seals<br />

X Ambient temperature above 40 °C Use high-temperature grease<br />

X X Inadequate lubrication Lubricate according to specifications<br />

X X Bearing fitted askew Check fitting, fit outer ring more lightly<br />

X X Too little bearing play Fit bearing with more play (only after<br />

consultation with the manufacturer)<br />

X X Bearing is corroded Replace bearing, check seals<br />

X Scalping points in the raceway Replace bearing<br />

X Scoring Replace bearing, avoid vibrations at<br />

standstill<br />

X Too much bearing play Fit bearing with less play (only after<br />

consultation with the manufacturer)<br />

[ID 568]<br />

5.6.4 Faults with the brushes<br />

Overview<br />

Note<br />

Changes to the brush complement or brush material may only be made in<br />

consultation with the manufacturer!<br />

Table 5-4 Faults with the brushes<br />

Overview - faults with the brushes<br />

Fault characteristics<br />

↓ Brush edges knocked out or splintered<br />

↓ High brush wear<br />

↓ High wear despite good commutation<br />

Possible causes of fault Remedial measures<br />

System fault<br />

SIEMENS AG T61160347010001 (DMHO V9)<br />

5-6 Operating instructions 1GG6286-0NA4.-1VV1-Z