Commissioning<br />

•= the carbon brushes in the brush boxes and the brush levers move easily and<br />

the spring action on all carbon brushes is even.<br />

•= brakes (if fitted) function perfectly.<br />

Before the <strong>motor</strong> is commissioned, the power converter must be commissioned in<br />

accordance with its operating instructions. The <strong>motor</strong> parameters must be taken<br />

into account.<br />

The work that has been carried out must be recorded in the relevant checklist.<br />

Notice<br />

After a lengthy period of storage or downtime (>2 years), the bearings should be<br />

relubricated or the grease replaced.<br />

Note<br />

In the case of <strong>motor</strong>s with an air-to-water heat exchanger, perform the test run<br />

without water cooling if there is expected to be a lengthy period between<br />

installation and the actual start of operation.<br />

[ID 551]<br />

4.3 Checking the insulation resistance<br />

Instructions relevant for safety<br />

Note<br />

Take note of the operating instructions for the insulation resistance meter used.<br />

Warning<br />

During the measurement, and immediately afterwards, some of the terminals are at<br />

hazardous voltage levels and must not be touched.<br />

If the supply feeder cables are connected, ensure that the line supply voltage<br />

cannot be connected.<br />

SIEMENS AG T61160347010001 (DMHO V9)<br />

Operating instructions 1GG6286-0NA4.-1VV1-Z 4-3