Installation and Assembly<br />

are transmitted virtually completely (rigid, unpressed wire end ferrules would<br />

reduce the clamping forces acting on the conductor and hence endanger the<br />

contact quality).<br />

[ID 531]<br />

3.5.5 Connecting auxiliary circuits<br />

Auxiliary circuit, general<br />

Brush monitoring<br />

Tacho-generator<br />

Terminal strips for conductor cross-sections of up to 2.5 mm 2 are installed for<br />

connecting the auxiliary circuits, such as temperature sensors or standstill heating.<br />

The information required to connect the auxiliary circuits is provided in the<br />

connection diagram, located on the inside of the terminal box cover, and in the<br />

<strong>motor</strong> documentation.<br />

Note<br />

The required insulation stripping length on conductors for auxiliary terminals differs<br />

according to terminal type (6 to 9 mm). When the length is correct, the bare<br />

conductor should reach to the central stop in the terminal and at the same time the<br />

conductor insulation should be run up to the contact part of the terminal.<br />

Depending on the design of the <strong>motor</strong>, signal transmitters may be installed for<br />

brush monitoring.<br />

The brush monitoring facility serves the purpose of detecting the limit value of the<br />

brush height. When a brush height of approximately 2 mm above the prescribed<br />

minimum brush height is reached, a signal is generated via a microswitch. In<br />

normal operation and at average speeds, this corresponds to a remaining running<br />

time of between 500 and 1000 operating hours. The carbon brushes must be<br />

replaced in good time.<br />

The electrical connection conditions are shown in the terminal diagram in the<br />

terminal box.<br />

With built-on tacho-generators the electrical connection is on the line-side; the<br />

supplementary operating instructions must be observed.<br />

Temperature monitoring<br />

Caution<br />

In the case of <strong>motor</strong>s with temperature sensors, their temperature evaluation and<br />

control system must be designed in such a way that danger from unexpected<br />

automatic restarting of the installation is ruled out following response of the<br />

temperature protection and subsequent cooling.<br />

SIEMENS AG T61160347010001 (DMHO V9)<br />

Operating instructions 1GG6286-0NA4.-1VV1-Z 3-13