Installation and Assembly<br />

3.5.2 Cable routing<br />

Cable entry and routing<br />

The unscrewable entry plate is supplied as standard without holes drilled so that<br />

the design, number and size of the cable glands can be adapted to the chosen line<br />

conditions.<br />

Cable entry components must:<br />

•= be adapted to the cable diameter and cable type.<br />

•= ensure degree of protection IP 55 (also applies to the screw-in point; use<br />

sealing washer and bonding).<br />

•= conform to the routing conditions (strain relief devices if cables are not fixed).<br />

Connecting cables and in particular protective conductors should be installed in an<br />

open arrangement in the terminal box and if possible with excess length in order to<br />

avoid chafing of the cable insulation.<br />

Unused cable entry holes must be sealed accordingly, ensuring that:<br />

•= the seals consist of resistant, approved material.<br />

•= the degree of protection is ensured (use sealing washer or bonding).<br />

•= they can only be opened with a tool.<br />

Note<br />

Unused cable entry holes must always be sealed with suitable sealing inserts.<br />

[ID 529]<br />

3.5.3 Connecting the ground conductor<br />

Overview<br />

The <strong>motor</strong>'s ground conductor cross-section must comply with the regulations for<br />

electrical installations (e.g. IEC/EN 60204-1).<br />

There is a hexagon bolt with flat and spring washer on the stator frame at the<br />

designated connecting point for the ground conductor. This is suitable to connect<br />

multi-core conductors with cable lugs or straps with appropriate conductor ends.<br />

When making connections, ensure that<br />

•= the contact surface is clean and bright, and is protected with a suitable anticorrosion<br />

agent, e. g. acid-free Vaseline.<br />

•= the flat and spring washers are located under the bolt head.<br />

•= the maximum permissible clamping thickness for the cable lug or strap of 10<br />

mm is not exceeded.<br />

SIEMENS AG T61160347010001 (DMHO V9)<br />

3-10 Operating instructions 1GG6286-0NA4.-1VV1-Z