Installation and Assembly<br />

strip, for example, or pinned. Where a belt power take-off is used, mount the <strong>motor</strong><br />

on sliding rails so as to be able to set the correct belt tension.<br />

Caution<br />

If the belt tension is too high, the bearings and shaft are at risk. It is essential to<br />

adhere to the permissible values in accordance with the manufacturer's<br />

specifications.<br />

[ID 527]<br />

3.5 Electrical connection<br />

3.5.1 Safety information<br />

Instructions relevant for safety<br />

General<br />

Connecting<br />

Danger<br />

All work on the <strong>motor</strong> at rest must always be carried out by qualified expert<br />

personnel with the <strong>motor</strong> in the disconnected state and secured to prevent<br />

restarting.<br />

Check safe isolation from the supply.<br />

The connection to the supply is made in the terminal box. Additional terminals are<br />

available for auxiliary circuits, with terminal strips for conductor cross-sections of up<br />

to 2.5 mm 2 .<br />

Depending on the type of construction, terminal post insulators or terminal boards<br />

are installed for connection of the excitation.<br />

The terminal boxes can be rotated through increments of 90° corresponding to the<br />

connection direction. In this case it must be ensured that the winding conductors<br />

are correctly rerouted. The arrangement of the insulating plate does not need to be<br />

changed. In unfavorable circumstances, for example given large cross-sections<br />

and a large number of conductors, the possibility of repositioning is partly restricted<br />

or requires special adaptive measures.<br />

It must be ensured that a permanent, safe electrical connection is retained.<br />

Use the assigned cable end components.<br />

SIEMENS AG T61160347010001 (DMHO V9)<br />

3-8 Operating instructions 1GG6286-0NA4.-1VV1-Z