3.3 Aligning<br />

Instructions relevant for safety<br />

Installation and Assembly<br />

Detailed specialist know-how is required about the necessary measures in order to<br />

correctly align and securely mount the equipment, e.g. for<br />

•= preparing the foundation,<br />

•= selecting and mounting the coupling,<br />

•= measuring the concentricity and axial eccentricity tolerances,<br />

•= axial and horizontal positioning.<br />

If personnel are not familiar with the necessary measures and working steps, we<br />

recommend that the services of the local SIEMENS service center are used.<br />

Vertical and horizontal position<br />

3.4 Mounting<br />

Mounting<br />

The following measures are required in order to compensate any radial offset at<br />

the coupling and to horizontally adjust the electric <strong>motor</strong> with respect to the driven<br />

load:<br />

•= Place shims under the <strong>motor</strong> feet to position it vertically and to avoid<br />

stressing/distorting the machines. The number of shims should be kept as low<br />

as possible i.e. stack as few as possible.<br />

•= To horizontally position the machine, push it laterally on the foundation and<br />

ensure that the axial position is maintained.<br />

•= When positioning the <strong>motor</strong>, ensure that there is a uniform axial gap around the<br />

coupling.<br />

[ID 526]<br />

Prerequisites for smooth, vibration-free running:<br />

•= Stable foundation design or stable machine suspension if flange-mounted.<br />

•= Precise alignment of the <strong>motor</strong>.<br />

•= Correct balancing of the parts to be mounted on the shaft end.<br />

To securely mount the <strong>motor</strong> and transfer the drive torque, use <strong>motor</strong> mounting<br />

bolts with the required strength class in accordance with ISO 898-1, e.g. 10.9.<br />

Note on different designs<br />

In the case of <strong>motor</strong>s with the shaft end facing upwards, it must be ensured that no<br />

water is able to enter the top bearing. Motors that are attached by their mounting<br />

feet to the wall because of their design must be supported from below by a wall<br />

SIEMENS AG T61160347010001 (DMHO V9)<br />

Operating instructions 1GG6286-0NA4.-1VV1-Z 3-7