Installation and Assembly<br />

Balancing<br />

Noise emission<br />

The rotor is dynamically balanced.<br />

For shaft ends with featherkeys, the balancing type is specified using the following<br />

coding on the face of the shaft end:<br />

•= Code "F" means balancing with a complete featherkey (standard version).<br />

•= Code "H" signifies balancing with half a featherkey (this is a special version<br />

which must be specifically ordered). this means, in order to maintain the<br />

balancing quality, it is necessary to cut back the part of the featherkey that<br />

protrudes out of the drive element and the shaft profile if the <strong>motor</strong> has a short<br />

power take-off element.<br />

Please make sure that the power take-off element is correctly balanced e.g. halfcoupling,<br />

pulley, etc. Power take-off element may only be fitted or removed using<br />

suitable equipment.<br />

Warning<br />

The featherkeys are only secured against falling out during transport. If the <strong>motor</strong><br />

has two shaft ends, and a power take-off element is only fitted to one end, steps<br />

must be taken to prevent the featherkey at the other end from being slung out. If<br />

the rotor has the type of balance "H", the featherkey must be cut back to roughly<br />

half of its normal length.<br />

Caution<br />

Remove the rotor shipping brace, if fitted.<br />

Pay attention to the information on the shaft end.<br />

Power take-off elements may only be fitted or removed using suitable equipment.<br />

When assessing the noise that is emitted at the workplace, it should be taken into<br />

account that the A-weighted mean sound pressure level, measured in accordance<br />

with DIN EN 21680-1, namely 70 dB(A), can be exceeded when the <strong>motor</strong> is<br />

operated under load.<br />

[ID 523]<br />

3.2.2 Motor installation<br />

Motor foundation<br />

The person responsible for the system must ensure resonance-free installation of<br />

the <strong>motor</strong>. DIN 4024 Part 2 must be observed with regard to the design of the<br />

foundation.<br />

SIEMENS AG T61160347010001 (DMHO V9)<br />

3-4 Operating instructions 1GG6286-0NA4.-1VV1-Z