Storing indoors<br />

Installation and Assembly<br />

Covers or tarpaulins used to protect the equipment against the weather must not<br />

make contact with the surfaces of the equipment. Ensure adequate air circulation<br />

by positioning wooden spacer blocks between the equipment and such covers.<br />

The storage rooms must be dry, free from dust, frost and vibrations and well<br />

ventilated. They must also provide protection against extreme weather conditions.<br />

The <strong>motor</strong>s must be protected against shock and humidity.<br />

Preservation (mothballing)<br />

If <strong>motor</strong>s are to be put into storage for longer than 6 months, then they must be<br />

checked every 6 months to ensure they are in good working order and any<br />

necessary maintenance work must also be carried out. All preservation measures<br />

taken must be documented so that they can be reversed before the <strong>motor</strong>s are put<br />

back into service. Slightly heat the windings of <strong>motor</strong>s constantly and ensure good<br />

air circulation.<br />

Caution<br />

If the <strong>motor</strong>s were supplied with a shipping brace, secure the rotor in accordance<br />

with the instructions for the shipping brace in order to prevent vibration damage to<br />

the bearings.<br />

If the <strong>motor</strong>s are equipped with condensate drain holes, remove the sealing plugs<br />

at regular intervals, let the condensate drain off and refit the plugs.<br />

[ID 521]<br />

3.2 Installation<br />

3.2.1 General installation instructions<br />

Instructions relevant for safety<br />

Cooling<br />

Caution<br />

Temperatures of up to or even over 100 °C can occur on the housings of electrical<br />

machines. Any contact must then be avoided. It must also be ensured that<br />

temperature-sensitive parts, such as normal cables or electronic components are<br />

not in contact with or fixed to the housing.<br />

Take careful note of the technical data specified in the <strong>motor</strong> documentation and<br />

on the plates on the <strong>motor</strong> frame! In addition, the following conditions for cooling,<br />

balancing quality and noise emission must be maintained:<br />

The cooling air must be able to be drawn-in and discharged unimpeded; ensure<br />

that warm discharged air is not drawn back in at the air intake.<br />