Description, technical data, certificates<br />

Figure 2-2 Schematic representation of machine type 1GG6<br />

Ventilation and cooling<br />

Terminal boxes<br />

Fan unit<br />

The machines are open-circuit ventilated with degree of protection IP23. The<br />

separately driven fan (cooling method IC06), normally mounted on the non-drive<br />

end, forces the cooling air through the machine. Optimized cooling-air passages in<br />

the stator and in the rotor ensure good heat dissipation from all windings, the<br />

laminated rotor core and the commutator.<br />

The terminal box has terminals for main circuits, shunt circuits (excitation) and, if<br />

appropriate, auxiliary circuits. The terminal boxes conform to degree of protection<br />

IP55.<br />

The unscrewable entry plate is supplied as standard without holes drilled so that<br />

the design, number and size of the cable glands can be adapted to the chosen line<br />

conditions.<br />

If a separate terminal compartment is prescribed for certain auxiliary circuits, an<br />

additional auxiliary terminal box must be mounted on the side of the box frame.<br />

The <strong>DC</strong> machine has a built-on fan unit that provides for separately driven<br />

ventilation.<br />

SIEMENS AG T61160347010001 (DMHO V9)<br />

2-4 Operating instructions 1GG6286-0NA4.-1VV1-Z