CE90WIN_EN_SP5
CE90WIN_EN_SP5
CE90WIN_EN_SP5
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>CE90WIN</strong>_<strong>EN</strong>_SP1<br />
Data Source<br />
ADAPT00155041<br />
Description:<br />
Patch ID: 35282832<br />
There is no support for the legacy NonStop ODBC/MP driver, Tdmsrv32.dll. Correct Outer Join syntax needs to be added for this<br />
driver.<br />
New Behavior:<br />
The correct SQL syntax, Sql2OuterJoin, has been added to the Lotus Notes join build list. Outer Join syntax for the legacy NonStop<br />
ODBC/MP Driver is now supported as well as the existing support for the NonStop ODBC/MX Driver.<br />
ADAPT00156292<br />
Description:<br />
Patch ID: 35340354<br />
When a native connection was made to an Informix database, there was a long delay when a user was bringing back a listing of<br />
objects in the database.<br />
New Behavior:<br />
A change has been made to allow the objects in the Informix database to return without delay when using a native connection.<br />
Designer<br />
ADAPT00125099<br />
Description:<br />
Patch ID: 34998719<br />
In an RDC application that uses the design time control (CRAXDDRT), when a user browses a field in the designer the recordset will<br />
be closed so that when a user previews the report, he or she will be prompted to log on again.<br />
New Behavior:<br />
In an RDC application that uses the design time control (CRAXDDRT), the rowset will not be closed until the report is closed.<br />
ADAPT00125717<br />
Description:<br />
Patch ID: 35044721<br />
When exporting to text and selecting not to paginate, the user is not prompted to specify the number of characters per inch for the text<br />
layout.<br />
New Behavior:<br />
A flag has been set to invoke the secondary dialog box when the user elects not to paginate when exporting to text.<br />
Destination - Disk<br />
ADAPT00167140<br />
Description:<br />
Patch ID: 35363139<br />
When you use the CRPE method PEOutputToWindow to display a report in a viewer window, an export to disk from that window<br />
does not prompt you for a save location. This occurs after applying the latest version of crpe32.dll (9.2.3.745) and u2ddisk.dll<br />
(9.2.1.543) only.<br />
New Behavior:<br />
The PEOutputToWindow method now automatically sets the PESetAllowPromptDialog method to "True". This enables the extra<br />
dialog prompts when you export to any format from the viewer window.<br />
DHTML Report Page Viewer (Com)