CHF14<br />
ADAPT00605690<br />
Description:<br />
Patch ID: 38,977,350<br />
The ConnectInit function, which lets parameters be set during connection initialization, has limited usefulness because it does<br />
not apply to all data sources.<br />
For example, if it were possible to apply the ConnectInit function to an Oracle data source, an Oracle connection could be<br />
opened with a security context that uses the CLIENT_IDENTIFIER session variable to filter the data returned to the user.<br />
ConnectINIT could set this variable.<br />
Other databases are requesting that type of security and parameter setting at connection initialization. For example, Informix<br />
queries prioritization, Oracle queries optimizer tuning, and Teradata queries auditing.<br />
New Behavior:<br />
This problem is resolved.<br />
To solve the problem, the ConnectInit function applies to all data sources. This fix has been created for Web <strong>Intelligence</strong> and<br />
Desktop <strong>Intelligence</strong> applications, working with thin client documents that are based on <strong>Business</strong> Objects universes.<br />
Known Limitations:<br />
If many instruction statements need to be set through the ConnectINIT function, it is recommended to do the following:<br />
1. Ensure that the configuration section of the PRM file for your database is set as follows:<br />
N<br />
2. When designing a Universe in the Desktop <strong>Intelligence</strong> Designer, avoid setting instructions into the ConnectINIT parameter in<br />
its current Universe connection to avoid potentially interfering with catalog information.<br />
ADAPT00606091<br />
Description:<br />
Patch ID: 39,213,051<br />
When users customize analytic in a viewer, unless users re-select the document that is associated with the analytic, an error<br />
message appears.<br />
The cause of the problem is that the reference to the document becomes lost.<br />
New Behavior:<br />
This problem is resolved<br />
ADAPT00606766<br />
Description:<br />
Patch ID: 39,238,599<br />
When users log on in offline mode, after the "offline" parameter has been set to True in a Desktop <strong>Intelligence</strong> SDK application,<br />
an error message appears : "Runtime error '306'."<br />
New Behavior:<br />
This problem is resolved.