CE10WIN_EN_SP4<br />
Repository<br />
ADAPT00349470<br />
Description:<br />
Patch ID: 37452882<br />
The Central Management Server (CMS) may freeze or terminate unexpectedly when it connects to a Business View from Crystal Reports.<br />
The cause of the problem is that the metadata SDK sends an empty security bypass token to the CMS, which results in the unexpected behavior.<br />
New Behavior:<br />
To solve the problem, when an empty security bypass token is received, a value of false is returned to deny the bypass. The result is that security<br />
is not bypassed, and the query runs, subject to the normal security rights checking.<br />
Repository migration<br />
ADAPT00417297<br />
Description:<br />
Patch ID: 37462186<br />
When reports are migrated from Crystal Enterprise 8.5, the Username and Password details are stripped by the Update Objects action. The<br />
affected reports are based on Dictionary or Query Files.<br />
The "UpdateInfoObject" function removes logon and password information if the property SI_SERVER name for the report and the migrating<br />
infoObject doesn't match, which is the case for reports that are based on Dictionary or Query Files.<br />
New Behavior:<br />
This problem is resolved.<br />
Scheduling destination<br />
ADAPT00135662<br />
Description:<br />
Patch ID: 36371507<br />
Reports that are scheduled to SMTP may show incomplete information in the date headers on non-English operating systems or non-English<br />
versions of Crystal Enterprise.<br />
The cause of the problem is that the SMTP RFC is set to accept English three-letter short month strings (Jan, Feb, Mar, and so on). The format<br />
function uses the current locale to retrieve the short month string, which in this case will in a language other than English. The non-standard date<br />
headers that are retrieved with non-English deployments of CE fail to be processed.<br />
New Behavior:<br />
The issue has been fixed by inserting the English short month string into the date header.<br />
Scheduling time<br />
ADAPT00420994<br />
Description:<br />
Patch ID: 37450586<br />
When using Publishing Wizard, a report that is scheduled to run "Daily" appears as scheduled to run every 24 hours (from the time that it was<br />
first set) in the Web Desktop and the Crystal Management Console (CMC).<br />
The recurrence pattern is set to "Hourly" every 24 hours when users choose "Daily."<br />
New Behavior:<br />
This problem is resolved.<br />