Service Pack Readme (Adapt)
Service Pack Readme (Adapt)
Service Pack Readme (Adapt)
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
CE10WIN_EN_SP2<br />
Platform .NET SDK<br />
ADAPT00300613<br />
Description:<br />
Patch ID: 36269538<br />
AD Authentication fails when SSO (Single Sign On) is used with the Crystal Enterprise SDK (ASP web app, COM thick client, and so on).<br />
This happens when the computer name of the machine that runs the CMS (Crystal Management Server) uses the domain name of the user who is<br />
logging on. The problem is caused by how the user’s domain membership is evaluated to determine if the user is a local account.<br />
New Behavior:<br />
Changes have been made to the way that the user's domain is evaluated. This change ensures that an exact match with the local domain is made<br />
first, before determining that the user is a local account and logging the user on to the system.<br />
ADAPT00300823<br />
Description:<br />
Patch ID: 36314869<br />
When a report that contains UFLs with saved data is viewed with the Report Application Server or .NET Web Viewer, the<br />
WhileReadingRecords formula is evaluated unnecessarily.<br />
The cause for the unnecessary evaluation is that the background thread is not cleaned up at the appropriate time, which causes the memory<br />
calculation function to fail. At that point, the formula believes it has changed size and causes the recurring formulas to invalidate themselves and<br />
re-evaluate.<br />
New Behavior:<br />
This problem is resolved.<br />
ADAPT00304000<br />
Description:<br />
Patch ID: 36302546<br />
The Crystal Enterprise .Net Web Viewer does not pass NULL parameter values correctly when it uses the Page Server. Instead, it passes a value<br />
of zero.<br />
The problem is that the Page Server does not verify the parameter value before sending it.<br />
New Behavior:<br />
This problem is resolved.<br />
ADAPT00321193<br />
Description:<br />
Patch ID: 36506640<br />
When an ADO.NET dataset is passed to a report that has been created from a Command object in a .NET application, the following errors<br />
message appears: "Source: CrystalDecisions.ReportAppServer.DataSetConversionDescription: Not implemented. Details: This operation cannot<br />
be performed on this type of connection. Error in File<br />
C:\DOCUME~1\lconnors\LOCALS~1\Temp\{63629073-C5EB-4CF4-831F-A8AB4D9E52B6}.rpt: Operation not yet implemented."<br />
This problem was introduced with release of patch CRPE32.DLL version 10.0.5.681.<br />
New Behavior:<br />
This problem is resolved.<br />
Platform COM SDK