CE10WIN_EN_SP2<br />

Platform .NET SDK<br />

ADAPT00300613<br />

Description:<br />

Patch ID: 36269538<br />

AD Authentication fails when SSO (Single Sign On) is used with the Crystal Enterprise SDK (ASP web app, COM thick client, and so on).<br />

This happens when the computer name of the machine that runs the CMS (Crystal Management Server) uses the domain name of the user who is<br />

logging on. The problem is caused by how the user’s domain membership is evaluated to determine if the user is a local account.<br />

New Behavior:<br />

Changes have been made to the way that the user's domain is evaluated. This change ensures that an exact match with the local domain is made<br />

first, before determining that the user is a local account and logging the user on to the system.<br />

ADAPT00300823<br />

Description:<br />

Patch ID: 36314869<br />

When a report that contains UFLs with saved data is viewed with the Report Application Server or .NET Web Viewer, the<br />

WhileReadingRecords formula is evaluated unnecessarily.<br />

The cause for the unnecessary evaluation is that the background thread is not cleaned up at the appropriate time, which causes the memory<br />

calculation function to fail. At that point, the formula believes it has changed size and causes the recurring formulas to invalidate themselves and<br />

re-evaluate.<br />

New Behavior:<br />

This problem is resolved.<br />

ADAPT00304000<br />

Description:<br />

Patch ID: 36302546<br />

The Crystal Enterprise .Net Web Viewer does not pass NULL parameter values correctly when it uses the Page Server. Instead, it passes a value<br />

of zero.<br />

The problem is that the Page Server does not verify the parameter value before sending it.<br />

New Behavior:<br />

This problem is resolved.<br />

ADAPT00321193<br />

Description:<br />

Patch ID: 36506640<br />

When an ADO.NET dataset is passed to a report that has been created from a Command object in a .NET application, the following errors<br />

message appears: "Source: CrystalDecisions.ReportAppServer.DataSetConversionDescription: Not implemented. Details: This operation cannot<br />

be performed on this type of connection. Error in File<br />

C:\DOCUME~1\lconnors\LOCALS~1\Temp\{63629073-C5EB-4CF4-831F-A8AB4D9E52B6}.rpt: Operation not yet implemented."<br />

This problem was introduced with release of patch CRPE32.DLL version 10.0.5.681.<br />

New Behavior:<br />

This problem is resolved.<br />