18.08.2013 Views

vSphere Storage - ESXi 5.1 - Documentation - VMware

vSphere Storage - ESXi 5.1 - Documentation - VMware

vSphere Storage - ESXi 5.1 - Documentation - VMware

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>vSphere</strong> <strong>Storage</strong><br />

n Coredump is not supported on any software FCoE LUNs, including the boot LUN.<br />

n Multipathing is not supported at pre-boot.<br />

n Boot LUN cannot be shared with other hosts even on shared storage.<br />

Best Practices for Software FCoE Boot<br />

<strong>VMware</strong> recommends several best practices when you boot your system from a software FCoE LUN.<br />

n Make sure that the host has access to the entire boot LUN. The boot LUN cannot be shared with other<br />

hosts even on shared storage.<br />

n If you use Intel 10 Gigabit Ethernet Controller (Niantec) with a Cisco switch, configure the switch port in<br />

the following way:<br />

n Enable the Spanning Tree Protocol (STP).<br />

n Turn off switchport trunk native vlan for the VLAN used for FCoE.<br />

Set Up Software FCoE Boot<br />

Your <strong>ESXi</strong> host can boot from a FCoE LUN using the software FCoE adapter a network adapter.<br />

When you configure your host for a software FCoE boot, you perform a number of tasks.<br />

Prerequisites<br />

The network adapter has the following capabilities:<br />

n Support partial FCoE offload (software FCoE).<br />

n Contain either a FCoE Boot Firmware Table (FBFT) or a FCoE Boot Parameter Table (FBPT).<br />

For information about network adapters that support software FCoE boot, see the <strong>vSphere</strong> Compatibility<br />

Guide.<br />

Procedure<br />

1 Configure Software FCoE Boot Parameters on page 64<br />

To support a software FCoE boot process, a network adapter on your host must have a specially<br />

configured FCoE boot firmware. When you configure the firmware, you enable the adapter for the<br />

software FCoE boot and specify the boot LUN parameters.<br />

2 Install and Boot <strong>ESXi</strong> from Software FCoE LUN on page 65<br />

When you set up your system to boot from a software FCoE LUN, you install the <strong>ESXi</strong> image to the target<br />

LUN. You can then boot your host from that LUN.<br />

Configure Software FCoE Boot Parameters<br />

To support a software FCoE boot process, a network adapter on your host must have a specially configured<br />

FCoE boot firmware. When you configure the firmware, you enable the adapter for the software FCoE boot<br />

and specify the boot LUN parameters.<br />

Procedure<br />

u In the option ROM of the network adapter, specify software FCoE boot parameters.<br />

These parameters include boot target, boot LUN, VLAN ID, and so on.<br />

Because configuring the network adapter is vendor specific, review your vendor documentation for<br />

instructions.<br />

64 <strong>VMware</strong>, Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!