3 From the list of available targets, select a target to configure and click Authentication.<br />

4 Deselect Inherit settings from parent and specify authentication method.<br />

n None<br />

n Use unidirectional CHAP if required by target<br />

n Use unidirectional CHAP unless prohibited by target<br />

n Use unidirectional CHAP<br />

n Use bidirectional CHAP. To configure bidirectional CHAP, you must select this option.<br />

5 Specify the outgoing CHAP name.<br />

Make sure that the name you specify matches the name configured on the storage side.<br />

n To set the CHAP name to the iSCSI adapter name, select Use initiator name.<br />

n To set the CHAP name to anything other than the iSCSI initiator name, deselect Use initiator name<br />

and type a name in the Name text box.<br />

6 Enter an outgoing CHAP secret to be used as part of authentication. Use the same secret that you enter<br />

on the storage side.<br />

7 If configuring bi-directional CHAP, specify incoming CHAP credentials.<br />

Make sure to use different secrets for the outgoing and incoming CHAP.<br />

8 Click OK.<br />

9 Rescan the iSCSI adapter.<br />

If you change the CHAP parameters, they are used for new iSCSI sessions. For existing sessions, new settings<br />

are not used until you log out and login again.<br />

Disable CHAP<br />

You can disable CHAP if your storage system does not require it.<br />

If you disable CHAP on a system that requires CHAP authentication, existing iSCSI sessions remain active<br />

until you reboot your host, end the session through the command line, or the storage system forces a logout.<br />

After the session ends, you can no longer connect to targets that require CHAP.<br />

Required privilege: Host.Configuration.<strong>Storage</strong> Partition Configuration<br />

Procedure<br />

1 Open the CHAP Credentials dialog box.<br />

2 For software and dependent hardware iSCSI adapters, to disable just the mutual CHAP and leave the oneway<br />

CHAP, select Do not use CHAP in the Mutual CHAP area.<br />

3 To disable one-way CHAP, select Do not use CHAP in the CHAP area.<br />

The mutual CHAP, if set up, automatically turns to Do not use CHAP when you disable the one-way<br />

CHAP.<br />

4 Click OK.<br />

Chapter 11 Configuring iSCSI Adapters and <strong>Storage</strong><br />

<strong>VMware</strong>, Inc. 107