Table 11-4. CHAP Security Level (Continued)<br />

CHAP Security Level Description Supported<br />

Use unidirectional CHAP unless<br />

prohibited by target<br />

The host prefers CHAP, but can use non-CHAP<br />

connections if the target does not support CHAP.<br />

Use unidirectional CHAP The host requires successful CHAP authentication. The<br />

connection fails if CHAP negotiation fails.<br />

Software iSCSI<br />

Dependent hardware iSCSI<br />

Independent hardware<br />

iSCSI<br />

Software iSCSI<br />

Dependent hardware iSCSI<br />

Independent hardware<br />

iSCSI<br />

Use bidirectional CHAP The host and the target support bidirectional CHAP. Software iSCSI<br />

Set Up CHAP for iSCSI Adapter in the <strong>vSphere</strong> Client<br />

Dependent hardware iSCSI<br />

You can set up all targets to receive the same CHAP name and secret from the iSCSI initiator at the initiator<br />

level. By default, all discovery addresses or static targets inherit CHAP parameters that you set up at the<br />

initiator level.<br />

The CHAP name should not exceed 511 alphanumeric characters and the CHAP secret should not exceed 255<br />

alphanumeric characters. Some adapters, for example the QLogic adapter, might have lower limits, 255 for the<br />

CHAP name and 100 for the CHAP secret.<br />

Prerequisites<br />

n Before setting up CHAP parameters for software or dependent hardware iSCSI, determine whether to<br />

configure one-way or mutual CHAP. Independent hardware iSCSI adapters do not support mutual<br />

CHAP.<br />

n In one-way CHAP, the target authenticates the initiator.<br />

n In mutual CHAP, both the target and the initiator authenticate each other. Use different secrets for<br />

CHAP and mutual CHAP.<br />

When you configure CHAP parameters, verify that they match the parameters on the storage side.<br />

n Required privilege: Host.Configuration.<strong>Storage</strong> Partition Configuration<br />

Procedure<br />

1 Access the iSCSI Initiator Properties dialog box.<br />

2 On the General tab, click CHAP.<br />

Chapter 11 Configuring iSCSI Adapters and <strong>Storage</strong><br />