J.5.1.2. IDTIME$<br />

Obsolete Entry Points, PROCs, and Routines<br />

The IDLINE$ call is the equivalent of IDLINE$, except that you furnish the date (in<br />

register R2) and time (in register R3) in ER DATE$ format. IDTIME$ can be used by a<br />

processor that executes for a considerable time before it prints the ID line. In this case,<br />

the actual date and time that the processor began execution are saved and then passed<br />

to IDLINE$ in registers R2 and R3.<br />

J.5.2. IDONLY$<br />

There are two entry points to the IDONLY$ routine: IDONLY$ and IDTOME$.<br />

J.5.2.1. IDONLY$<br />

IDONLY$ generates the ID line without the symbolic element cycle information.<br />

IDONLY$ can be used by processors that do not create or update elements. An<br />

externally defined PARTBL is not required.<br />

Calling Sequence<br />

LMJ X11,IDONLY$<br />

.<br />

PF FORM 12,6,18<br />

LA A0,(PF 1,7,IDBUFF)<br />

ER PRINT$<br />

J.5.2.2. IDTOME$<br />

The IDTOME$ call is the equivalent of IDONLY$, except that you furnish the date (in R2)<br />

and time (in R3) in ER DATE$ format.<br />

J.6. SFDT$–MASM Calling Sequence<br />

The S$FDT PROC to call the SFDT$ routine is replaced by the S$FDT$ PROC (see<br />

22.1.2).<br />

The S$FDT procedure call obtains the standard format for date, time, or both date and<br />

time:<br />

S$FDT pkt-addr date time<br />

error return<br />

normal return<br />

where:<br />

pkt-addr<br />

the address of the five-word SFDT$ packet.<br />

7833 1733–004 J–15