Subfield Control Word<br />

The following 1-word entry provides information about the subfield.<br />

Bits 0–5<br />

Field Type (FT)<br />

Bits 6–11<br />

INFOR Information<br />

Indicates whether the subfield is in the command field or in the specification<br />

field. The possible values are<br />

0 Command field<br />

1 Specification field<br />

Field Number (FN)<br />

Bits 12–17<br />

The field number (within the field type) that contains the subfield. In the<br />

processor call statement, fields are numbered beginning with 1, left to right, and<br />

are separated by commas. The highest field number is 63. If more than 63<br />

fields are entered in the processor call statement, the 64th and following fields<br />

are numbered beginning with 1.<br />

Subfield Number (SFN)<br />

Identifies which part of the filename.eltname notation is being described by the<br />

subfield. The possible values are<br />

1 File qualifier<br />

2 File name<br />

3 File cycle<br />

4 Read key<br />

5 Write key<br />

6 Element name<br />

7 Version name<br />

8 Element cycle<br />