Table 18–6. SAR$: WRITE Procedure SW$CALLST Codes<br />

Octal Code Status<br />

SAR$ WRITE<br />

011 The value for SW$OUTBUFL is too small; use the word length returned in<br />

SW$RECBUFL.<br />

012 An I/O error has occurred in a WRITE procedure. See the SW$IOSTAT field<br />

for the status code and Table 18–7.<br />

013 An invalid value is specified for SW$OUTRECT.<br />

014 An incorrect ACD subroutine version is being used with SAR$.<br />

015 The attribute table contains an index that is either zero, not in sequential<br />

order, or greater than the text length.<br />

016 The attribute table contains an invalid attribute type or an invalid value for the<br />

attribute type.<br />

017 An illegal character set type is specified in the SW$OCHART field.<br />

020 Line numbers are not allowed for this output file type.<br />

021 The WRITE packet is not initialized; a call to S$AROPENO must be made<br />

before calls to S$ARWRITE or S$ARCLOSO.<br />

022 The image buffer has overflowed; use the word length returned in<br />

SW$RECBUFL for the SW$IMGBUFL field and call S$ARWRITE again.<br />

024 An error has occurred in adding the element to the table of contents; see T1<br />

of the SW$STATUS field for the ER PFI$ status code and the Exec ER<br />

<strong>Programming</strong> <strong>Reference</strong> <strong>Manual</strong>.<br />

026 An error has occurred in executing the symbiont file closing breakpoint; see<br />

T1 of the SW$STATUS field for the ER CSF$ status code and the Exec ER<br />

<strong>Programming</strong> <strong>Reference</strong> <strong>Manual</strong>.<br />

027 SDF control records cannot be written to this output file type.<br />

030 Symbiont write control records cannot be written to this output file type.<br />

031 The file name buffer address in the FIP is zero; an address of an SDF file<br />

name must be specified.<br />

032 The file name buffer address in the FIP is zero; an address of a symbiont file<br />

name must be specified.<br />

033 The element name buffer address in the FIP is zero; an address of an SDF<br />

element name must be specified.<br />

034 An illegal value is specified for the file name buffer byte length in the FIP;<br />

legal values are from 1 to 12.<br />

035 An illegal value is specified for the element name buffer byte length in the<br />

FIP; legal values are from 1 to 12.<br />

036 An illegal value is specified for the version name buffer byte length in the FIP;<br />

legal values are from 1 to 12.<br />

037 The output I/O buffer address (SW$OUTBUF) is zero; this buffer must be<br />

provided when writing to an SDF file or element.<br />