SR$UNTRFLG<br />

The untranslate mode flag setting.<br />

0<br />

1<br />

SR$SDFCNTL<br />

SAR$ READ<br />

Untranslate mode is off: an error is returned if SAR$ reads a character set type<br />

other than 00 (Fieldata), 01 (ASCII/ISO), 077 (ACD) (default), or ASCII-like.<br />

Untranslate mode is on: all input is passed to the caller untranslated.<br />

This field specifies which SDF control records to return to the caller. Bits 0 to 31<br />

may be set by the caller, where bit 0 is the leftmost bit of the field. If bit n is set, the<br />

control record type (n + 040) is returned to the caller. The image control word of the<br />

control record is returned in SR$SDFICW, and any data words of the control record<br />

are returned in the text buffer. If this field is set to zero, no control records are<br />

returned to the caller (default).<br />

Note that the control record type 051 is not returned unless it is used to continue a<br />

type 061 control record. Therefore, it is suggested that the caller specify that type<br />

051 records be returned if type 061 records are desired, and vice-versa.<br />

SR$ADDRSEC<br />

The mass storage sector address of the next image to be read. This field is used if<br />

the image to be read is not the next sequential image. If this field is set to zero, the<br />

next sequential image is read (default). It is undefined if the input is not from an SDF<br />

file or element. This field contains SR$ADDRWO in S1 of the word.<br />

SR$ADDRWO<br />

The word offset into the mass storage sector address of the next image to be read.<br />

This field is used if the image to be read is not the next sequential image. If this<br />

field is set to zero, the next sequential image is read (default). This field is undefined<br />

if the input is not from an SDF file or element.<br />

17.2.1.3. Information Returned by READ Procedures<br />

The following fields of the READ packet contain values returned to the calling program<br />

by the SAR$ READ procedures.<br />

SR$STATUS<br />

The READ function status word; it contains the call status in H2, the substatus in T1,<br />

and the I/O status in S3.<br />

7833 1733–004 17–23