18.08.2013 Views

Quality Assurance Handbook for Rural Roads Volume-I - pmgsy

Quality Assurance Handbook for Rural Roads Volume-I - pmgsy

Quality Assurance Handbook for Rural Roads Volume-I - pmgsy

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

3. Section-900<br />

2. Lower centering gradually and uni<strong>for</strong>mly so as to permit the concrete to take self weight, uni<strong>for</strong>mly<br />

and gradually to avoid shock or vibration. At reentrant angles of concrete sections, remove<br />

<strong>for</strong>mwork soon after setting of concrete to prevent shrinkage cracking.<br />

3. When internal metal ties are permitted, remove them or their parts without damaging concrete.<br />

Fill the holes left out with cement mortar (1:3)<br />

4. The time of removal of <strong>for</strong>mwork when OPC is used without any admixtures is given in Table<br />

900.1 Otherwise it may be taken as 14 days <strong>for</strong> Superstructure.<br />

A 4 Reuse of Formwork<br />

TABLE 900.1: TIME FOR REMOVAL OF FORMWORK<br />

1. After dismantling examine individual components <strong>for</strong> damage and remove damaged pieces <strong>for</strong><br />

rectification.<br />

2. Straighten all bent steel propos be<strong>for</strong>e reuse, the maximum deviation from straightness being 1/<br />

600 th of its length. Reduce permissible axle loads on props by a minimum of 10 percent after each<br />

reuse, depending on their condition.<br />

B. <strong>Quality</strong> Control Requirements<br />

1 Tolerances in Formwork<br />

Member No. of days<br />

Walls, piers, abutments, columns and vertical faces 0.5 to 2<br />

of structural members<br />

Soffit of slab (with prop left under) 3<br />

Props (left under slabs) 14<br />

Soffit of girders (with props left under) 7<br />

Props (left under girders) 21<br />

(a) Deviations <strong>for</strong>m the specified dimensions of cross + 12 mm<br />

section of columns, beams - 6 mm<br />

(b) Deviations dimensions of footing/open foundation<br />

(i) Dimensions in plan + 50 mm<br />

(ii) Eccentricity in plan 0.02 times the width - 12 mm<br />

of the footings in the direction of deviation<br />

but not more than 50 mm<br />

(iii) Thickness ± 0.05 times the<br />

specified thickness<br />

152

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!