HIGH ACCURACY<br />

THERMOCOUPLE CONTROL<br />

FAST COOLDOWN<br />

SOFTWARE TEMPERATURE<br />

CONTROL LOOP<br />

TEMPERATURE RAMPING<br />

AUTOMATIC PROFILING<br />

RECIPE STORAGE<br />

TEMPERATURE ALARM<br />

INTRODUCTION<br />

The DTC's Analog to <strong>Digital</strong> converter gives<br />

temperature resolution to 0.05.<br />

The DTC provides temperature control using spike<br />

thermocouples at the outside of the process tube or<br />

paddle thermocouples inside the tube.<br />

This optional feature provides shorter cooling time<br />

for a higher production capacity.<br />

The temperature control uses a cascading PID loop<br />

of the spike or paddle thermocouple input signals.<br />

Gain control is provided for limiting the maximum<br />

power output.<br />

<strong>Temperature</strong> ramping is provided on all zones. This<br />

guarantees a long flat zone during and ramping up<br />

or down, by making use of calculated values from a<br />

profile table or continuously controlling the<br />

temperature using the paddle thermocouples<br />

Automatic profiling is continuously possible during<br />

the process or by means of specially programmed<br />

recipes.<br />

DTC and DPC versions 2I and higher provide an<br />

unlimited number of temperature setpoints in a<br />

process recipe.<br />

An alarm is generated when the temperature rise<br />

above or fall below programmable limits. The alarm<br />

limits can be in the range 0.1-25.5 oC.<br />

BROKEN THERMOCOUPLE ALARM An alarm is generated when a thermocouple is<br />

broken. In spike control the affected zone is<br />

maintained at approximate temperature by using the<br />

thermocouple break output table measured during<br />

profiling. If the zone is in paddle control and the<br />

thermocouples fails control is switched to the spike<br />

thermocouple.<br />

DIGITAL TEMPERATURE CONTROLLER REFERENCE MANUAL 1-2