3.3 Conveyer furnaces<br />

DTC CONFIGURATION<br />

All Conveyor Furnaces require the <strong>Controller</strong> Unit and either the Program and Display Unit<br />

or the Touch Screen Display . The difference in configuration depends on the heated length<br />

(number of control zones) and the width of the zones (whether or not side zone control is<br />

used). This will not only affect the number of boards in the <strong>Controller</strong> Unit, but also the type<br />

of Output Expander Unit used and the number of boards therein. If zones 13, 14 and 15 are<br />

not used as control zones, they can be used for profiling or temperature measurement.<br />

3.3.1 Small band conveyors<br />

The system configuration is solely dependent on the number of control zones used:<br />

a) For 1 to 6 Control Zones<br />

The system will consist of the <strong>Controller</strong> Unit and the Program and Display Unit or<br />

the Touch Screen Display , containing one or two, 3 channel input boards and one<br />

or two, 3 channel output boards. The number of input boards will be the same as<br />

the number of output boards.<br />

For example: To control 2 zones, one input board and one output board is necessary.<br />

b) For more than 6 Control Zones<br />

Besides the <strong>Controller</strong> Unit fitted with an Output Expander Interconnection board<br />

and the Program and Display Unit or the Touch Screen Display. An Output<br />

Expander Unit A has to be added to the configuration. The <strong>Controller</strong> Unit will<br />

contain the appropriate number of input boards (1 board for every 3 control zones)<br />

and an Output Expander Interconnection board placed in the first output board slot.<br />

The Output Expander Unit A will contain between 3 and 5 output boards depending<br />

on the number of control zones. There must be the same number of input and<br />

output boards.<br />

3.3.2 Broadband conveyors<br />

For the broadband conveyors or small band conveyors with accurate crossbelt temperature<br />

control, gain control on the two side zones is needed. The system requires the <strong>Controller</strong><br />

Unit fitted with an Output Expander Interconnection board and either the Program and<br />

Display Unit or the Touch Screen Display;, and the Output Expander Unit B. The<br />

differences in configuration stem from the number of control zones used.<br />

a) For 1 to 9 Control Zones<br />

The <strong>Controller</strong> Unit is fitted with one to three input boards (1 board for every 3<br />

control zones). Output Expander Unit B contains an output board for each zone,<br />

which triggers the main zone and it's 2 side zones.<br />

b) For more than 9 Zones<br />

The <strong>Controller</strong> Unit is fitted with four or five input boards (1 board for every 3<br />

control zones). Output Expander Unit B contains the maximum nine output boards.<br />

It is, therefore, necessary that Output Expander Unit C is used, containing one<br />

board for each zone greater than nine.<br />

DIGITAL TEMPERATURE CONTROLLER REFERENCE MANUAL 3-3