3.DTC Configuration<br />
3.1 Introduction<br />
DTC CONFIGURATION<br />
The units that can be combined to give the desired configuration are shown in Figure 3-1. All<br />
systems have to contain the <strong>Controller</strong> Unit and the Touch Screen Display.<br />
3.2 Diffusion furnaces<br />
All Diffusion Furnaces require a data input unit (Touchscreen or TSC-II). The <strong>Controller</strong><br />
Unit is also required, but it must be configured according to the type of furnace to be<br />
controlled. This dependents on the number of input and outputs required.<br />
3.2.1 Furnace with DPC<br />
The DTC <strong>Controller</strong> Unit is configured with two or four input boards and one or two output<br />
boards, giving control of up to 6 zones. Automatic Profiling and paddle control is possible if<br />
one (or two) of the input boards is placed in position E (and D).<br />
Communication to the DPC is provided by the communication board. It allows reception of<br />
temperature recipe selections from the DPC and provides temperature information to the<br />
DPC.<br />
The temperature can be ramped in each zone, either independently or under master/slave<br />
control (see section 3.4).<br />
3.2.2 Stand-alone<br />
The DTC <strong>Controller</strong> Unit is configured with two or four input boards and one or two output<br />
boards, depending on the tube configuration (3, 5 or 6 zones). For Automatic Profiling or<br />
control on the paddle thermocouples, a board has to be placed in position ‘E’ (Figure 3-1<br />
DTC Configurations) for the first 3 zones and position ‘D’ for the zones 4, 5 and 6. Boards<br />
for the spike are in position ‘A’ for the first three zones and ‘B’ for the next.<br />
In this configuration, the DTC controls the temperature in all zones of the furnace tube. The<br />
temperature can be ramped in each zone, either independently or under master/slave control<br />
(see section 3.4). The unit can store and run a maximum of 16 recipes.<br />
3.2.3 Furnace with source furnace, stand-alone<br />
The DTC <strong>Controller</strong> Unit is configured with three input boards and two output boards,<br />
giving control of 6 zones (3 in the main furnace and 3 in the source furnace). Automatic<br />
Profiling and paddle control is possible if one of the input boards is placed in position E.<br />
All the zones may be automatically profiled or paddle controlled. The temperature can be<br />
ramped in each zone of the main furnace and source furnace, either independently or under<br />
master/slave control (see section 3.4).<br />
DIGITAL TEMPERATURE CONTROLLER REFERENCE MANUAL 3-1