SYSVAR, <strong>cont'd</strong>.<br />

Chapter 2 Program Instructions<br />

Remarks, <strong>cont'd</strong>. 19. Type of error message (Set or Read)<br />

Four types of error messages can be selected:<br />

SYSVAR(19) = 1 in line (default)<br />

e.g. “Invalid font in line 10”<br />

SYSVAR(19) = 2 Error in line : <br />

e.g. “Error 19 in line 10: Invalid font”<br />

SYSVAR(19) = 3 E<br />

e.g. “E19”<br />

SYSVAR(19) = 4 Error in line <br />

e.g. “Error 19 in line 10”<br />

The presently selected type of error message can also be read and is returned<br />

as a numeric value (1 – 4), by e.g PRINT SYSVAR(19).<br />

20. Direct or transfer mode (Read only)<br />

SYSVAR(20) allows you to read if the printer is set up for direct thermal<br />

printing or thermal transfer printing, which is decided by your choice of paper<br />

type in the printer's setup.<br />

The printer returns:<br />

0 = Direct thermal printing<br />

1 = Thermal transfer printing<br />

21. Printhead density (Read only)<br />

SYSVAR(21) allows you to read the density of the printer's printhead,<br />

expressed as number of dots per millimetre.<br />

22. Number of dots (Read only)<br />

SYSVAR(22) allows you to read the number of dots in the printer's printhead.<br />

23. Transfer ribbon sensor (Read only)<br />

SYSVAR(23) allows you to read the status of the transfer ribbon sensor in<br />

thermal transfer printers.<br />

The printer returns:<br />

0 = No ribbon detected<br />

1 = Ribbon detected<br />

24. Power up since last SYSVAR(24) (Read only)<br />

This system variable is important when using the <strong>Intermec</strong> Direct Protocol.<br />

At power up, all data not saved as programs, files, fonts or images will be<br />

deleted, and most instructions will be reset to their respective default values.<br />

SYSVAR(24) allows the host to poll the printer to see if a power up has<br />

occurred, e.g. because of a power failure, and – if so – download new data and<br />

new instructions.<br />

The printer returns:<br />

0 = No power up since last SYSVAR(24)<br />

1 = Power up has occurred since last SYSVAR(24)<br />