Contents, cont'd. - Intermec
Contents, cont'd. - Intermec
Contents, cont'd. - Intermec
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
SETUP, <strong>cont'd</strong>.<br />
Chapter 2 Program Instructions<br />
Remarks, <strong>cont'd</strong>. SETUP WRITE returns the printer's setup in the following order (the<br />
example shows default values for a standard EasyCoder 501 XP printer):<br />
SETUP WRITE uart1:<br />
yields:<br />
SER-COM,UART1,BAUDRATE,9600<br />
SER-COM,UART1,CHAR LENGTH,8<br />
SER-COM,UART1,PARITY,NONE<br />
SER-COM,UART1,STOPBITS,1<br />
SER-COM,UART1,FLOWCONTROL,RTS/CTS,DISABLE<br />
SER-COM,UART1,FLOWCONTROL,ENQ/ACK,DISABLE<br />
SER-COM,UART1,FLOWCONTROL,XON/XOFF,DATA FROM HOST,DISABLE<br />
SER-COM,UART1,FLOWCONTROL,XON/XOFF,DATA TO HOST,DISABLE<br />
SER-COM,UART1,NEW LINE,CR/LF<br />
SER-COM,UART1,REC BUF,300<br />
SER-COM,UART1,TRANS BUF,300<br />
FEEDADJ,STARTADJ,0<br />
FEEDADJ,STOPADJ,0<br />
MEDIA,MEDIA SIZE,XSTART,36<br />
MEDIA,MEDIA SIZE,WIDTH,1244<br />
MEDIA,MEDIA SIZE,LENGTH,1800<br />
MEDIA,MEDIA TYPE,LABEL (w GAPS)<br />
MEDIA,PAPER TYPE,TRANSFER<br />
MEDIA,PAPER TYPE,DIRECT THERMAL,LABEL CONSTANT,70<br />
MEDIA,PAPER TYPE,DIRECT THERMAL,LABEL FACTOR,30<br />
MEDIA,PAPER TYPE,TRANSFER,RIBBON CONSTANT,100<br />
MEDIA,PAPER TYPE,TRANSFER,RIBBON FACTOR,25<br />
MEDIA,PAPER TYPE,TRANSFER,LABEL OFFSET,0<br />
MEDIA,CONTRAST,0%<br />
#MEDIA,TESTFEED,10 3 (Info only. Comparator 0–15; amplifier 0–7)<br />
PRINT DEFS,HEAD RESIST, 1166 (Info only)<br />
PRINT DEFS,PRINT SPEED,150<br />
Note that when a SETUP WRITE file is used to change the setup, the printer's<br />
present TESTFEED adjustment is not affected.<br />
SETUP FILES & SETUP STRINGS<br />
The methods of manual setup via the printer's built-in keyboard are described<br />
in the Installation & Operation manuals for the various printer models. Setup<br />
files and strings can also be used to change the setup as a part of the program<br />
execution, or to change the setup by remote control from the host.<br />
A setup file may contain new values for one or several setup parameters,<br />
whereas a setup string only can change a single parameter. Another difference<br />
is that, while the creation of setup files requires several operations, setup<br />
strings can be created in a single operation which makes them suitable for use<br />
in the Immediate and Direct Modes, e.g. in the <strong>Intermec</strong> Direct protocol.<br />
When a SETUP statement is encountered, the setup will be changed<br />
accordingly, then the program execution will be resumed. Note that some<br />
printing instructions (ALIGN, DIR, FONT, and PRPOS) may be changed<br />
when test labels are printed.<br />
<strong>Intermec</strong> Fingerprint 7.2 – Reference Manual Ed. 3 207