PORTOUT ON/OFF<br />

Chapter 2 Program Instructions<br />

Field of Application Statement for setting one of four relay port or one of eight optical ports<br />

on an Industrial Interface Board to either on or off.<br />

Syntax PORTOUT () ON|OFF<br />

is the number of the port to be set:<br />

OUT ports (relay): 201 – 204<br />

OUT ports (optical): 221 – 228<br />

Remarks This statement works with the Industrial Interface Board and is able to control<br />

8 IN ports with opto-couplers, 8 OUT ports with opto-couplers, and 4 OUT<br />

ports with relays. For information on how to read the status of the various<br />

ports, please refer to the PORTIN function.<br />

This feature is intended to allow the execution of the <strong>Intermec</strong> Fingerprint<br />

program to control various external units like gates, lamps or conveyor belts.<br />

Please refer to the documentation of the Industrial Interface Board for more<br />

information.<br />

Example The relay of OUT port 201 on an Industrial Interface Board is Opened and<br />

then Closed like this:<br />

. . . . .<br />

. . . . .<br />

1000 PORTOUT (201) ON<br />

. . . . .<br />

. . . . .<br />

2000 PORTOUT (201) OFF<br />