<strong>9560</strong> <strong>Transaction</strong> <strong>Manager</strong> User’s <strong>Manual</strong><br />

2-8<br />

The status is stored as follows:<br />

• The #0 register contains a 3-digit binary string.<br />

• A 1 indicates a signal has been detected; a 0 indicates no signal.<br />

• The digits correspond to the inputs as shown in the following diagram:<br />

Third input<br />

J3<br />

0 1 1 Register #0<br />

Second input<br />

J2<br />

First input<br />

J1<br />

<strong>9560</strong>-40U<br />

For example, if the #0 register contains 011, it would indicate a signal at the<br />

first and second inputs, but none at the third input.<br />

The following diagram shows a typical connection to a sense input. In this<br />

example, a normally open door sense switch is wired in series with the sense<br />

input and a secondary power circuit. When the door switch is closed, the sense<br />

input detects the 24V output from the power circuit.<br />

Sample Sense Input Application<br />

Input Range Selection<br />

Jumper Block<br />

Terminal<br />

Block<br />

Normally Open Door<br />

Sense Switch<br />

330 1200<br />

1 2 3<br />

1 2 3<br />

Secondary circuit of no<br />

more than 24 VDC or VAC<br />

and no more than 60 mA.<br />

4 5<br />

Optical<br />

Isolator<br />

For 5-14V input, jumper pins 1 and 2.<br />

For 14-24V input, jumper pins 2 and 3.<br />

<strong>9560</strong><br />

External<br />

<strong>9560</strong>-03U