<strong>9560</strong> <strong>Transaction</strong> <strong>Manager</strong> User’s <strong>Manual</strong><br />

Reader “Hung Up”...<br />

Possible Causes Try This<br />

IRL program looping. Remove power from unit. Press and hold the Exit IRL<br />

switch (located on connector board) while restoring<br />

power.<br />

Exit IRL Switch<br />

10-4<br />

J17<br />

Slot Scanner Does Not Function...<br />

Possible Causes Try This<br />

Exit<br />

IRL<br />

Switch<br />

<strong>9560</strong>-47U<br />

Incorrect ink type. Repeat scan with a bar code printed with carbonbased<br />

ink.<br />

Reader Beeps Continually on Power Up...<br />

Possible Causes Try This<br />

Internal magnetic card reader is attached and<br />

communications settings were changed before<br />

power loss.<br />

Configure the reader to 9600 Baud, even parity, 7<br />

data bits, and 1 stop bit. See “Using the Magnetic<br />

Card Reader” in Chapter 4.