Data Entry Commands - Preamble B<br />

Preamble B<br />

Purpose: Enters up to 25 characters into the Preamble B buffer to be transmitted with<br />

the data. For an explanation of Preambles, see Chapter 5, “Data<br />

Communications and Operating Options.”<br />

Terminal /<br />

Keyboard<br />

Host: ++data++<br />

8-26<br />

If you enter the Preamble B command without entering data, then the<br />

preamble buffer is cleared.<br />

If you enter a single space or you enter data from the terminal, all<br />

subsequent data is stored in the preamble/postamble buffer until you send<br />

the Enter command (**) or until the buffer overflows.<br />

Ctrl B data Enter Ctrl B Enter<br />

Scan: To enter Preamble B:<br />

1. Scan this label:<br />

Enter Preamble B<br />

*++*<br />

*++*<br />

2. Scan up to 25 characters from the full ASCII chart in Appendix B, “Full<br />

ASCII Chart.”<br />

3. Scan this label:<br />

Enter<br />

**<br />

**<br />

Or: To clear Preamble B, scan this label:<br />

Clear Preamble B<br />

*++*<br />

*++*