Baud Rate<br />

Configuration Commands - Baud Rate<br />

Purpose: Defines the data transfer speed. It must match the baud rate of the device<br />

(host) that the reader is communicating with.<br />

For Polling Mode D, the baud rate must be 1200 or higher. For Multi-Drop<br />

protocol, the baud rate must be 2400 or higher.<br />

Default: 9600<br />

Syntax: IAdata<br />

Acceptable values for data are:<br />

0 110<br />

1 300<br />

2 600<br />

3 1200<br />

4 2400<br />

5 4800<br />

6 9600<br />

7 19200<br />

Scan: Scan one of these labels:<br />

110 2400<br />

*$+IA0$-* *$+IA4$-*<br />

*$+IA0$-* *$+IA4$-*<br />

300 4800<br />

*$+IA1$-* *$+IA5$-*<br />

*$+IA1$-* *$+IA5$-*<br />

600 9600<br />

*$+IA2$-* *$+IA6$-*<br />

*$+IA2$-* *$+IA6$-*<br />

1200 19200<br />

*$+IA3$-* *$+IA7$-*<br />

*$+IA3$-* *$+IA7$-*<br />

7<br />

7-7