Based on the calculations presented in Table 3-33, the total methane emissions <strong>from</strong> Site #2 are<br />

estimated by calculating the sum of the average of the total methane emissions <strong>from</strong> the<br />

bioreactor and control cells, which is 7,300 kilograms per day. It should be noted that this<br />

estimated value is extrapolated <strong>from</strong> a limited amount of flux data, and does not take into<br />

account diurnal or seasonal trends in methane emissions.<br />

3.2.4 Summa Canister Sampling<br />

Summa canister samples were collected <strong>from</strong> the gas collection header pipe in triplicate at Site<br />

#2. These samples represent a composite of LFG <strong>from</strong> the entire site. Samples were collected<br />

upstream of the vacuum pump to minimize loses and contamination. Blanks were also collected<br />

using a nitrogen gas stream to purge the VOST train condensers and glassware. Samples were<br />

analyzed using Methods TO-15, 25-C, a C1 through C6 alkane hydrocarbons analysis by<br />

GC/FID, and a permanent gases (O2, N2, CO2) analysis by GC/TCD. Results are presented in<br />

Tables 3-33 through 3-35. TO-15 results are qualified using results <strong>from</strong> the nitrogen blank. Any<br />