Half or cut bricks shall not be used except where necessary to complete the bond.<br />

Overlap in stretcher bond is usually half brick and is obtained by commencing each<br />

alternate course with a half brick. The overlap in header bond which is usually half<br />

the width of the brick is obtained by introducing a three quarter brick in each<br />

alternate course at quoins. In general, the cross joints in any course of brickwork<br />

shall not be nearer than a quarter of brick length from those in the course below or<br />

above it.<br />

6.8 Uniformity.<br />

The brickwork shall be built in uniform layers; corners and other advanced work<br />

shall be raked back. No part of a wall during its construction shall be raised more<br />

than one metre above the general construction level, to avoid unequal settlement.<br />

Parts of walls left at different levels shall be properly raked back. Toothing may be<br />

done where future extension is contemplated but shall not be used as an alternative<br />

to taking back.<br />

For half brick partition to be keyed into main walls, indents shall be left in the main<br />

walls.<br />

6.9. Thickness of joints.<br />

The thickness of joints shall be 10mm + 3 or – 3mm, unless otherwise specified.<br />

Thickness of joints shall be kept uniform. Slight difference to thickness of bricks<br />

shall be adjusted within joint thickness. Where brickwork is to match the existing<br />

work, the joints shall be of the same thickness as in the existing work.<br />

6.10 Striking joints.<br />

Where no pointing, plastering or other finish is indicted, the green mortar shall be<br />

neatly struck flush. Where pointing, plastering or other finish is indicated, the joints<br />

shall be squarely raked out to a depth not less than 10mm for plastering and 15mm<br />

for pointing.<br />

GTS : General Technical Specification. Page 47